Hedler Daylight DX15 Operation Manual Download Page 2

H E D L E R   S y s t e m l i c h t   G m b H       H e e r s t r a s s e   1 1 2       D - 6 5 5 9 4   R u n k e l   /   L a h n       w w w . h e d l e r. c o m
Te l e f o n   +   4 9   -   ( 0 )   6 4 8 2   9 1 8   1 0 0       Te l e f a x   +   4 9   -   ( 0 )   6 4 8 2   9 1 8   1 1 1       e M a i l   i n f o @ h e d l e r. c o m

Daylight DX15 / DF15

TECHNICAL DATA DX15

Type: DX15 

 

Voltage: 230 V ~ 2,0A   50/60 Hz 

 

Power: 150 Watt 

 

Risk group: 1-RG

Color: CRI > 95 

 

Kelvin: 5600K 

Safety class system: I   

Protection category: IP30

Weight: 2600g 

 

Ambient temperature (Ta): -15° - +40° C   

Surface temperature: 85°C

Light stand attachment: 5/8“ 

Safety glass code: < 2051 > 

 

Light unit code: < 1511 > 

Bulb code: < 1501 >

   Safety 

clearance: 

      Position: 

 

 

 

Under any circumstances do not under-run the safety   

 

 

Tilt light unit max.

 

 

 

clearances given within the graphic to inflammable material! 

 

 

45° upwards/down-  

           wards 

in 

operation!

HEDLER

®

S y s t e m l i c h t

max. +45°

max. -45°

top

1m

0,5m

0,5m

TECHNICAL DATA DF15

Type: DF15 

 

Voltage: 230 V ~ 2,0A   50/60 Hz 

 

Power: 150 Watt 

 

Risk group: 1-RG

Color: CRI > 95 

 

Kelvin: 5600K 

Safety class system: I   

Protection category: IP30

Weight: 2900g 

 

Ambient temperature (Ta): -15° - +40° C   

Surface temperature: 85°C

Light stand attachment: 5/8“ 

Fresnel lens code: < 6507 > 

 

Light unit code: < 1516 > 

Bulb code: < 1501 >

   Safety 

clearance: 

      Position: 

 

 

 

Under any circumstances do not under-run the safety   

 

 

Tilt light unit max.

 

 

 

clearances given within the graphic to inflammable material! 

 

 

45° upwards/down-  

           wards 

in 

operation!

max. +45°

max. -45°

top

1m

0,5m

0,5m

OPERATION MANUAL

Summary of Contents for Daylight DX15

Page 1: ...e QuickFit adapter for attaching all of the HEDLER lightformers quickly and easily Interchangeable reflectors with bayonet ring can be attached in the following way place the rim of the ring into the...

Page 2: ...nce Position Under any circumstances do not under run the safety Tilt light unit max clearances given within the graphic to inflammable material 45 upwards down wards in operation HEDLER S y s t e m l...

Page 3: ...the socket wrench which was delivered with the DF15 After loosening the socket screw completely remove the cover plate guard Turn the focusing knob until the DF15 has its maximum spot light position P...

Page 4: ...6482 918100 www hedler com PLEASE NOTE SPECIAL SET UP ADVICE Light units of the HEDLER DX and DF range have an up side and an underside setting up the light unit it is important to take care of the co...

Page 5: ...nit s in hospital s museum s factory factories asf with permission of the appropriate responsible public authority administration company management or business management only If not taking care of t...

Page 6: ...use a Hedler light unit with a defective safety glass a defective Pyrex cover a defective flash bulb defective bulb s and or defective fuse s Never put a Hedler light unit into operation with a defec...

Page 7: ...flectors parts of softboxes and reflex umbrellas and some accessories completely after using them and before packing them away not doing so can cause serious burnig and or the risk of sparking Not use...