trouble 

shooting

If your Refrigerator, Freezer appliance develop a fault, please check the following table.

Fault  

Probable Cause  

Action

The appliance is not working

  

The unit is not switched on  

Check that the unit is plugged in

   

 

correctly and switched on

   

   

Plug and/or lead are damaged  

Call our agent or qualified technician

   

   

Power supply  

Check power supply

   

   

Internal wiring fault 

Call our agent or qualified

   

 

technician

The appliance turns on, but the

 

Too much ice on the evaporator  

Defrost the appliance

temperature is too high/low

 

   

Condenser blocked with dust  

Clean the condenser thoroughly by

   

 

qualified technician

   

   

The door is not shut properly  

Check that the door is shut and  

   

 

seals are not damaged

   

   

Appliance is located near a heat 

Move the refrigerator to a more

   

source, or air flow to the 

suitable location

   

condenser is blocked

   

Ambient temperature is too high  

Increase ventilation or move  

 

   

 

appliance to a cooler position

   

   

Unsuitable foodstuffs are being  

Remove any excessive hot

   

stored in the appliance 

foodstuffs or blockages to the fan

   

Appliance is overloaded  

Reduce the amount of food stored

   

 

in the appliance

The appliance is leaking water

 

The appliance is not properly  

Adjust the screw feet to level the

(Refrigerator) 

levelled 

appliance

   

The discharge outlet is blocked  

Clear the discharge outlet

   

   

The water container is damaged  

Call our agent or qualifi ed technician

The appliance is unusually loud

   Loose nut/ screw  

Check and tighten all nuts and screws

   

   

The appliance has not been  

Check installation position and

   

installed in a level or stable position  change if necessary

Summary of Contents for UC01GD

Page 1: ... mike hebvest com operator s manual Commercial Single Door Undercounter Coolers performance reliability simplicity Model No Description UC01SD Commercial Single Stainless Steel Door Undercounter Cooler UC01GD Commercial Single Glass Door Undercounter Cooler ...

Page 2: ...e manufacturer its service agent or similarly qualified persons in order to avoid a hazard 19 This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety IEC603365 1 20 Child...

Page 3: ... panel How to see the set point Push and immediately release the SET key the set point will be showed Push and immediately release te SET key again or wait about 5s to return to normal visualization How to change the set point Push the SET key for more than 2 seconds to chagne the set point value The value of the set point will be displayed and the oC start blinking To change the set value push th...

Page 4: ...diately release the key the set point will be showed and starts blinking To change the set value push or arrows within 20s To memorize the new set point value push the key again or wait 20s Manual Defrost The appliance will automatically run a defrost cycle every 12 hours Note the cycle starts from the time the appliance is initially powered up To manually defrost the applicance Press and hold the...

Page 5: ...will last 20 minutes Note Starting a manual defrost also resets the automatic defrost timer The next automatic defrost will start 6 hours after the manual defrost has finished Freezer Manual defrosting by switching off and disconnecting the wait until all the ice inside has been melted The condensation water must be collected Never use a sharp or pointed object that may damage the freezer refriger...

Page 6: ...hebvest com t 800 469 8908 f 407 264 6309 mike hebvest com Commercial Single Door Undercounter Coolers changing the door hinge 2 Remove the hinge 2 3 Take off the door ...

Page 7: ...hebvest com t 800 469 8908 f 407 264 6309 mike hebvest com Commercial Single Door Undercounter Coolers changing the door hinge 4 Remove the hinge 1 5 Change two hinges positions 6 Fix the hinge1 ...

Page 8: ...hebvest com t 800 469 8908 f 407 264 6309 mike hebvest com Commercial Single Door Undercounter Coolers changing the door hinge 7 Remove Hinge 4 Lower door hinge 8 Remove Hinge 3 Upper door hinge ...

Page 9: ...vest com t 800 469 8908 f 407 264 6309 mike hebvest com Commercial Single Door Undercounter Coolers changing the door hinge 9 Exchange Hinge 3 and Hinge 4 s position 10 Fix Hinge 3 and Hinge 4 on the door ...

Page 10: ...hebvest com t 800 469 8908 f 407 264 6309 mike hebvest com Commercial Single Door Undercounter Coolers changing the door hinge 11 Turn the door up side down and connect to the upper hinge 12 Fix Hinge2 ...

Page 11: ...wet Do not use abrasive cleaning agents These can leave harmful residues Use only mild soapy water Clean the door seal with water only Ensure that no cleaning water penetrates into the electrical components Must not be cleaned by a water jet Always wipe dry after cleaning with a soft cloth Take care when cleaning the rear of the appliance An agent or qualified technician must carry out repairs if ...

Page 12: ...hebvest com t 800 469 8908 f 407 264 6309 mike hebvest com Commercial Single Door Undercounter Coolers wiring diagram STANDARD ...

Page 13: ...perly Check that the door is shut and seals are not damaged Appliance is located near a heat Move the refrigerator to a more source or air flow to the suitable location condenser is blocked Ambient temperature is too high Increase ventilation or move appliance to a cooler position Unsuitable foodstuffs are being Remove any excessive hot stored in the appliance foodstuffs or blockages to the fan Ap...

Reviews: