Fill in small sum of fuel into the fuel tank, make sure fuel pipe is connected properly, and no
leakage in fuel supply system. Fill in fuel to proper level.
Connect the po) battery cable to the battery po) terminal. Connect the other end of
the positive (+) battery cable to the generator positive (+) terminal.
Connect the negative (-) battery cable to the battery negative (-) terminal. Connect the other end of
the negative (-) battery cable to the generator negative (-) terminal.
1-4.1 How to start generator’
Turn the switch “POWER” to “ON” position. The controller is energized. It indicates “000V” by
LED screen. Connect the plug of electrical appliances to the socket on the generator panel. Press
the green button “ON” , the generator will start automatically. AC voltage is indicated by
LED after generator starts.
Press the yellow button “MENU” , real-time voltage, currency, frequency and cumulative
time is indicated orderly. Indicator lights of frequency and cumulative time will turn on in the
right part of the panel.
If you need 120V AC output, please turn the transfer switch left to “120V” position, and turn
circuit breaker to “ON” position. If you need AC 120/240V, please turn the transfer switch right to
“120/240V” position, and turn circuit breaker to “ON” position.
When you use the transfer switch, please turn circuit breaker to “OFF” position at first.
1-4.2 How to stop and reset generator
Take off the load of generator; turn the circuit breaker to “OFF” position. Press the red button
“OFF” , the generator will stop automatically. Then turn the switch “POWER” to “OFF”
position.
When generator fails to start or when error happens, alarm light will stay on in the controller
module, and fault code will be displayed in the LED. The fault code will tell you the probable
reasons. Press the red button “OFF”, reset the module, remove the fault code, and alarm light goes
out at the same time. Re-start the generator after the fault is cleared.
If you want to lay the generator idle for a long time, please drain the fuel, disconnect the battery
before the generator is put away.
3