background image

Remote Control Operation

 

LED / Control Panel

 

Receiver is located on the 
heater.

 

• 

To use the remote controller, 
aim the transmitter to the 

 

heater. A line of sight 

 

transmission is required for the 
unit to function.

 

• 

The controller does not have a 
protection rating. The 

 

controller must be kept away 
from wet applications.

 

• 

The remote will function at 
distances of over 2m when 
used in a straight line. This 
distance reduces when used 
at an angle.

 

Signal Transmitter

 

Temperature Control Button

 

• 

Temperature will be ad-
justed from L1

-

L2

-

L3

 

 

Heater settings 

 

L1: Low

 

L2: Medium 

 

L3: High

 

Timer

 

• 

Timer function 0

-

24 hour, 

press through hours to 
set the timer

 

 

Battery

 

• 

1 x CR2025  Battery 

 

required for operation. 

 

On/Off Button

 

• 

Press this button once to 
turn on/off for operation

 

Summary of Contents for TF2200RB

Page 1: ...Ph 03 9562 3455 E sales thermofilm com au www heatstrip com au TF2200RW Product Installation Manual TF2200RW Off White Electric Radiant Heater With Remote ...

Page 2: ...for DIY installation Direct overhead ceiling mounting is the preferred mounting method Features Benefits Specifications Model TF2200RW Heater Type Electric radiant overhead heater Power 230 240 Volts Nominal at 50 60Hertz Single Phase 2200Watts 9 2 Amps Connection 1 5M long 3 Core Cable 2 5mm2 with Plug Approvals Australia NZ Heating Area m2 3 4 Mounting Height MINIMUM RECOMMENDED MAXIMUM Mounting...

Page 3: ...g The timer function has 0 24 hour timer This feature is ideal for applications such as alfresco areas restaurant dining assembly line production etc when continuous heat is not required The timer also reduces the likelihood of heaters being inadvertently left turned on Remote pairing All units operate using the same remote control frequency therefore multiple heaters can be operated using a singl...

Page 4: ...st be kept away from wet applications The remote will function at distances of over 2m when used in a straight line This distance reduces when used at an angle Signal Transmitter Temperature Control Button Temperature will be ad justed from L1 L2 L3 Heater settings L1 Low L2 Medium L3 High Timer Timer function 0 24 hour press through hours to set the timer Battery 1 x CR2025 Battery required for o...

Page 5: ...ights between 2 3m 2 4m are optimal Electrical connections GPO s should not be located at the back of the heater They should be located outside the physical footprint of the units to minimize heat build up behind the units If the heater is to be mounted on an incline e g vaulted ceiling ensure the electrical connection is located at the lowest point of the heater Heater can be plugged directly int...

Page 6: ...r in small rooms when they are occupied by persons not capable of leaving the room on their own unless constant supervision is provided Angled Ceiling Installation Ceiling Installation Angled Wall Installation LIGHT FAN OR SPRINKLER MUST NOT BE BELOW HEATER LIGHT FAN OR SPRINKLER MUST NOT BE BELOW HEATER LIGHT FAN OR SPRINKLER MUST NOT BE BELOW HEATER SURFACE BELOW SURFACE BELOW SURFACE BELOW ...

Page 7: ...rt No PACKAGED DIMENSIONS mm WEIGHT kg MATERIAL ZBRAK 155 125 x 150 x 40 0 2 ALLOY The HEATSTRIP TF2200RB comes with a pair of standard mounting brackets These adjustable brackets allow direct ceiling or wall mount and come with preset angle options of parallel 22 5 and 45 ...

Page 8: ... while it is turned on Do not touch any part until 30 minutes after it is turned off This appliance is not intended for use by persons including children with reduced physical sensory or intellectual capabilities or lack of experience and knowledge unless they have been given supervision or instruction concern ing use of the appliance by a person responsible for their safety Children should be sup...

Page 9: ...he faulty product or components by Thermofilm or an authorized representative of Thermofilm Thermofilm does not participate in any site related costs or labour expenses incidental to replacement of parts repairing removing installing servicing transportation or handling of parts to complete products and assumes no liability on parts repaired or replaced without written authorisation Thermofilm sha...

Reviews: