O

THER

P

OTENTIAL FAULTS

odour, smoke or spark 

omitted on initial use

Strange sounds, odour, white

smoke omitted on initial use

Strange sound while igniting or

flameout

Flame or Sparkle appearing

from the outlet during ignition.

This is normal. Because at the beginning

there are air and dust mixed in the burning.

Wait for some time they will disappear.

When the air in the pipe is expelled, the

phenomenon will disappear.

The metal parts of the heater expand and

contract causing the noise. This is normal.

Fuel and air of last time were left in the oil

pipe of the nozzle, so the air and fuel are

not proper mixed, the burning isn’t

continuous. Sparkle is caused by the

residual carbon powder. This is normal.

11

Trouble Shooting

Please use the guide below before returning the product.

S

YMPTOM

/P

ROBLEM

Heater does not start

No power

Power-cut

Smoke/dust/fire from outlet 

Low Voltage

Wrong Frequency 

The quality of fuel is bad 

Filter blocked

Water is mixed in the tank

Flame goes out while burning

Fuel tank air hole blocked 

Fuel exhausted

Filter blocked

Flame does not ignite

Water is mixed in the tank

Fuel leaks

Fuel drain screw loose 

S

OLUTION

Make sure the power is connected

Switch the unit on when power is restored

Ensure unit is supplied the correct voltage

Use the defined frequency on Rating Label

Clean fuel tank and refill fresh fuel 

Check and replace the filter

Clean the fuel tank

Clean the hole on the fuel tank cap

Fill the tank with fuel

Check and replace the filter

Clean the fuel tank

Tighten the screw

HSFAH30_instructions  13/7/15  12:55  Page 11

Summary of Contents for HSFAH30

Page 1: ...ALWAYS BE FOLLOWED PLEASE READ ALL INSTRUCTIONS CAREFULLY AND RETAIN FOR FUTURE REFERENCE IF IN ANY DOUBT ABOUT THE INSTALLATION OR USE OF THIS PRODUCT CONSULT A COMPETENT ELECTRICIAN HSFAH30 Forced Air Heater Installation and Operating Instructions HSFAH30_instructions 13 7 15 12 55 Page 1 ...

Page 2: ...ted area the volume of air to be heated m3 heat output kW ratio must be at least 10 1 and people must be advised not to remain in the heated area for prolonged periods If people are required to be present in the heated area the volume of air to be heated m3 heat output kW ratio must be at least 30 1 Ventilation must be to the outside of the premises in which the heater is to be operated Minimum Ve...

Page 3: ...r inlet rear and air outlet front of the heater and DO NOT use duct work in front or at the rear of the heater DO NOT allow children or animals near the heater when in use or whilst still hot WARNING RISK OF ELECTRIC SHOCK DO NOT expose the heater to water spray rain dripping water or wind DO NOT operate the heater when you are tired or under the influence of alcohol drugs or intoxicating medicati...

Page 4: ... and the operator to read understand and comply with the following You must check all electrical products before use to ensure that they are safe You must inspect power cables plugs sockets and any other connectors for wear or damage You must ensure that the risk of electric shock is minimised by the installation of appropriate safety devices A Residual Current Circuit Breaker RCCB should be incor...

Page 5: ...and check all connections to ensure that none is loose DO NOT pull or carry the appliance by the power cable DO NOT pull the plug from the socket by the cable DO NOT use worn or damaged cables plugs or connectors Immediately have any faulty item repaired or replaced by a qualified electrician When a BS 1363 A UK 3 pin plug is damaged cut the cable just above the plug and dispose of the plug safely...

Page 6: ... guard E Motor assembly F Fuel tank G Lower tube frame H Power plug I Power switch J Start up switch K Control panel L Wheel M Fuel tank cap N Lower shell Q Fuel Gauge Overview of heater parts and dimensions Figure 1 Part Names Figure 2 Dimensions HSFAH30_instructions 13 7 15 12 55 Page 6 ...

Page 7: ...ws in the holes respectively and use a screw driver to tighten them by the same way Before operation Never use high volatile fuel such as petrol ONLY diesel or kerosene Only fill the fuel tank when the heater stops running and the flame goes out Please use diesel or No JIS1 kerosene Never use degenerative impure diesel or kerosene When you fill the fuel tank the tank filter must be installed If di...

Page 8: ... Filling the tank Operation Ignition Check the fuel tank and ensure there is sufficient fuel in it DO NOT stand or place any object less than 3m from the heater output and keep the heater a minimum of 2m from any walls or objects see figure 5 above Insert the plug in the socket Put the POWER switch to position 1 the indicator lights up Press the IGNITION button the motor begins to run and the spar...

Page 9: ... is restored the indicator will light but the heater will not work Please press the START switch to start up the heater How the heater works 9 Figure 6 A Combustion chamber B Spark plug C Fan blade D Motor E Pump F Air intake filter G Air output filter H Fuel tank I Controller J Air inlet pipe K Electrovalve assembly L Flame steady plate M Oil nozzle Description of working principles Press the STA...

Page 10: ... driver to remove the fuel plug from the tank and pull down the transparent fuel pipe Remove the old filter and replace with a new one Re install the transparent fuel pipe and fuel outlet plug Insert it in the tank and connect the fuel inlet pipe see above figure 7 Check the fuel tank When there is waste and water in the tank clean and drain the fuel tank How to drain the fuel tank see above figur...

Page 11: ...powder This is normal 11 Trouble Shooting Please use the guide below before returning the product SYMPTOM PROBLEM Heater does not start No power Power cut Smoke dust fire from outlet Low Voltage Wrong Frequency The quality of fuel is bad Filter blocked Water is mixed in the tank Flame goes out while burning Fuel tank air hole blocked Fuel exhausted Filter blocked Flame does not ignite Water is mix...

Page 12: ...23 5375 Fax 0117 923 5374 Victoria Road Avonmouth Bristol BS11 9DB www heatstore co uk Specification HSFAH30 RATING 30kW 10500BTU 25 800 Kcal h MOTOR POWER 180W OPERATING PRESSURE 30kW output 0 75 Bar AIR OUTPUT 752m3 h continuous usage 9 hours FUEL TYPE Diesel Oil Kerosene FUEL CONSUMPTION 2 5 litre h FUEL TANK CAPACITY 24 litres DIMENSIONS 870L x 470W x 520H mm WEIGHT 19 62kG HSFAH30_instruction...

Reviews: