WARNING - THIS APPLIANCE MUST BE EARTHED
The electrical installation must be carried out by a competent electrician, and be in strict
accordance with the current I.E.E. Regulations for Electrical Equipment in Buildings. The
wires in this mains lead are coloured in accordance with the following code:
GREEN AND YELLOW:
EARTH
BLUE: NEUTRAL
BROWN: LIVE
The heater is fitted with a length of flexible cable type H05VV-F size 3 x 1.0mm
2
for
connection to the fixed wiring of the premises through a suitable connection box
positioned adjacent to the heater. A means for disconnection must be incorporated in
the fixed wiring of the premises in accordance with the wiring rules. The supply circuit to
the heater must incorporate a double pole isolating switch having a contact separation
of at least 3mm.
Supplementary Earth Bonding
Should Equipotential Earth Bonding be required the earthing conductor in the supply
cord is deemed to provide the supplementary bonding connection (see Regulation
544.2.5, 17th Edition I.E.E. Wiring Regulations).
Please note that lit cigarettes, candles and oil burners, combined with the convection
effect of electric heaters can cause soot deposits to build up on the surface directly
above and to the sides of the heater. This is not a fault of the heater. Extensive burning
of candles or smoking in the operating environment of this product can produce heavy
discolouration within a few months of use.
This heater is filled with a precise quantity of special oil. Repairs requiring opening of the
oil container are only to be made by the manufacturer or his service agent who should be
contacted if there is an oil leakage.
Regulations concerning the disposal of oil when scrapping the appliance have to be
followed.
Safety - Overheat protection
For your safety this appliance is fitted with a thermal cut-out. In the event that the
product overheats for some reason, the cut-out prevents excessive temperatures on the
product by cutting the power to the heater. Once the heater has cooled down, it will
reset automatically, it will continue to cycle on and off automatically until the reason for
overheating is removed. The display screen may flash red to indicate the product has
overheated. To reset the display, remove the obstruction and hold Enter for 10 seconds.
3