background image

The 

Options

 menu allows the settings to be modified to suit the 

user’s preferences. These are;

DST Rule

 - Select your daylight saving setting. The heater 

clock will automatically adjust for daylight saving (British 
Summer Time as it is often referred to). If no adjustment is 
required then select none.

Auto Lock

 - Enable or disable the auto lock feature. This feature 

locks the interface if left inactive for longer than one minute. 
To unlock the appliance, press and hold 

Back

 and 

Enter

 for 

two seconds.

Sound

 - Audio feedback can be enabled or disabled.

Service Info

 - Service information is displayed.

Temp Units

 - Choose whether your unit displays degrees 

centigrade or Fahrenheit.

Advance

Boost

Options

Home All Day

Comfort On

Advance

Comfort On

Advance 1hr

DST Rule

Auto Lock

Sound

Service Info

Temp Units

Options

The 

Advance

 function allows the heating profile of the heater 

to be changed temporarily. When a timer has been selected, the 

Advance

 function is used to begin the next 

Comfort On

 mode 

early. If the heater is in 

Comfort Off

 mode and heat is required, 

press the 

Advance

 button.

If the heater is in 

Comfort On

 and heat is not required, press the 

Advance

 button and the heater will turn off until the beginning 

of the next 

Comfort On

 period. If the heater is in 

Manual

Eco 

Mode

 or 

Frost Protect

 and pressing the 

Advance

 button will 

switch off the heater. The heater will remain off until the 

Advance

 

button is pressed again.

The 

Advance

 button is also used to enter the 

Boost

 mode which 

provides temporary heating for one, two, three or four hours. 
Press the 

Advance

 button twice to begin a one hour boost. 

Continue pressing the 

Advance

 button to set longer boost 

period.

16

Summary of Contents for HSDI1000

Page 1: ... carefully and retained for future use Note also the information presented on the appliance Dynamic Intelirad Aluminium Radiator Models HSDI330 HSDI500 HSDI750 HSDI1000 HSDI1500 HSDI2000 OPERATING INSTRUCTION MANUAL 08 53191 0 ISSUE 5 ...

Page 2: ...kept away unless continuously supervised Children aged from 3 years and less than 8 years shall only switch on off the appliance provided that it has been placed or installed in its intended normal operating position and they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children aged from 3 years and less than 8 years ...

Page 3: ...te that lit cigarettes candles and oil burners combined with the convection effect of electric heaters can cause soot deposits to build up on the surface directly above and to the sides of the heater This is not a fault of the heater Extensive burning of candles or smoking in the operating environment of this product can produce heavy discolouration within a few months of use This heater is filled...

Page 4: ...10 Control Functions 11 Setting the Date and Time 12 Energy Saving Tips 18 Main Screen 12 Modes of Operation 13 Important 19 General 6 8 Quick Start Guide Choosing and Setting a Mode 14 Advance Boost Options Child Lock User Information 4 ...

Page 5: ...Intelirad Aluminium Radiator incorporates fin technology that optimises the heat distribution and reduces the warm up time Inteli Open window technology Should a window or door be accidentally left open your heater will detect the change in temperature and go into a standby mode returning to normal operation when the window or door has been closed This stops the heater from trying to warm the room...

Page 6: ...ig 1 and Fig 2 DO NOT locate the heater immediately below a fixed socket outlet or connection box 1 Remove wall mounting brackets from the protective packaging and locate the wall mounting template 2 Using the template drill and plug the mounting holes specific to your particular model see Fig 3 3 Fix the top wall mounting brackets securely to the wall using the screws provided 4 The bottom wall m...

Page 7: ...Fig 2 Fig 1 150 mm Min 150 mm Min 570 mm A mm 115 mm Shelf 300 mm Fig 3 Template 7 ...

Page 8: ...is automatically adjusted in spring and autumn between Greenwich Mean Time GMT and British Summer Time BST Set the Temperature The temperature shown on the display is the room temperature set point This is the temperature that the heater will maintain during the heating periods If the room temperature is above this temperature then the heater will not operate The heater leaves the factory with thi...

Page 9: ...If the heater is in a Comfort Off period and you want heat press the Advance button If the heater is in Comfort On and you don t want heat press the Advance button and it will go off until the beginning of the next Comfort On period Advance Boost The Advance button is also used to enter the boost mode which provides temporary heating for one two three or four hours Press the Advance button twice t...

Page 10: ...abling the room temperature to be controlled The minimum room temperature is 7 C The maximum temperature is set to 26 C by default however this can be increased to 32 C if required A temperature of 21ºC represents a normal room temperature 1 Display Screen 2 Menu Button 3 Back Button 4 Up and Down Arrows 5 Enter Button 6 Heating Status 7 Advance Button Operation NOTE Should the heater not operate ...

Page 11: ...19 C Green Screen 20 21 C White Screen 22 C Red Screen 5 Enter is used within the menu options to confirm settings On the main screen pressing Enter will display the enabled features 6 Heating Status is the timed periods during which the heater is providing heat are defined as Comfort On this is displayed at the bottom of the screen While constant heat modes are active the mode of operation is dis...

Page 12: ...e To adjust the time or date follow the steps below Press the Menu button Select Date Time by pressing the Enter button Press and to select the correct day of the month and press Enter to select Repeat this operation until the date and time has been set ensuring to press Enter to select Press Back button to return to the Main Screen once Set has been displayed Main Screen Setting the Date and Time...

Page 13: ...sed if you just want to protect the property from frost while you are away 4 User Timer provides greatest flexibility to the user Four time slots are available throughout the day and these can be customised for each day of the week The heater can also maintain a constant room temperature using the following modes 1 Manual mode heats the room to a comfortable temperature of 21 C 2 Eco Mode maintain...

Page 14: ... choose this timer option Preview view the times currently set Modify change the times currently set When Modify is chosen select and change each option using the and Enter buttons At the end of each period select Next to move to the following period When a day is complete select Save to update it Once the first day has been set up it is possible to copy these settings to successive days or all da...

Page 15: ...perature to be maintained during this period and press the Enter button At the end of the holiday mode the heater will automatically revert back to the previously selected programme Constant Heat Modes To choose a constant heat mode press Menu and to select Mode and press Enter Then select the required mode again using the Enter button NOTE If the anticipatory control is enabled the heater will ma...

Page 16: ...n Advance 1hr DST Rule Auto Lock Sound Service Info Temp Units Options The Advance function allows the heating profile of the heater to be changed temporarily When a timer has been selected the Advance function is used to begin the next Comfort On mode early If the heater is in Comfort Off mode and heat is required press the Advance button If the heater is in Comfort On and heat is not required pr...

Page 17: ...or disable This heater will function with bluetooth once App software is complete not available until 2017 EcoStart ES to achieve the desired temperature at the onset of the timed Comfort On period the appliance anticipates when it needs to start heating prior to the onset of the timed on period E g room is 16 C with 21 C at 7am set on the timer With ES on the control will start to heat the room b...

Page 18: ...ains at dusk to stop heat escaping through the windows 5 Windows Nearly 25 of heat loss can occur through poorly insulated frames and single glazing If you can t afford to double glaze all your windows go for the rooms you heat most 6 Treat your hot water tank Give it a jacket An insulating jacket for hot water tanks costs only a few pounds and pays for itself within months Fit one that s at least...

Page 19: ... covered with the following warranties 3 Years on site Warranty 3 years electronics Warranty 10 years Aluminium Body Warranty After sales service If the Heatstore Intelirad appears damaged when first received or does not function correctly contact us by phone 0117 923 5375 or email enquiries heatstore co uk Do not return the product in the first instance as this may delay us providing you with a s...

Page 20: ... 50 0 75 1 00 1 50 2 00 kW Minimum heat output indicative Pmin N A N A N A N A N A N A kW Maximum continous heat output Pmax c 0 33 0 50 0 75 1 00 1 50 2 00 kW Auxiliary electricity Consumption At nominal heat output elmax 0 00 0 00 0 00 0 00 0 00 0 00 kW At minium heat output elmin 0 00 0 00 0 00 0 00 0 00 0 00 kW In standby mode elSB 0 0012 0 0012 0 0012 0 0012 0 0012 0 0012 kW Type of heat outp...