HeatStar 1000ID Operating Instructions And Owner'S Manual Download Page 13

Fuel Fired Forced Air Indirect Construction Heater

Operating Instructions and Owner’s Manual

13

POS

P/N

ALT#

DESCRIPTION

01

50146

G06113-9010

Outlet cone

02

50148

G06077

Chimney fitting

03

50436

G06174

Insulating panel

04

50437

G06176

Combustion chamber

05

G06119-9010

Upper body

06

G06121-9010

Inspection panel

07

50438

G06178-9010

Lower body

08

50160

E10678-110

Motor

09

50161

E11230

Capacitor

08

E10771

Motor

09

E10771-1

Capacitor

10

50163

G06125-9010

Air conveyor

11

50165

T10260

Fan 

12

50167

P30169

Inlet grill

13

50051

I40330

Flex diesel pipe

14

50729

I20104

Iron fitting

16

50054

G06104-9005

Filter support bracket

20

50055

I40329

Flex diesel pipe

21

50168

P20174-9005

Handle

22

40477

C30355

Pipe cap

23

50169

P20175-9005

Support

24

50060

I40331

Flex diesel pipe

25

50061

I30696

Suction pipe

26

50063

I30737

Brass fitting

27

50064

G06068-9005

Power cord support

28

50435

G06110-9005

Fuel tank

29

50070

C30367

Tank cap

30

G06464-9005

Wheel axle

31

50068

G06106-9005

Wheels axle support bracket

32

C10510

Wheel

34

M20507

Cotter pin

35

50428

I25020

Drain cap

36

40476

C30375

O-ring

37

50434

G00248

El. control box

39

50077

P50127

Control box cover

40

G06407-9010

Base

42

50411

C30372

Cable protection

43

50085

E50102

Safety thermostat 

44

50173

M20107

Washer 

45

50418

G06181

Blast tube

46

50413

E20671

Terminal board

47

50419

G06183

Air adjustment shutter

48

G01061-1

Air flap

50043

G01061-2

Air flap

49

50246

G06153

El. Control box panel

50

50093

E20508

Fuse holder

51

50092

E10313

Fuse 

53

E20319

Ground terminal board

POS

P/N

ALT#

DESCRIPTION

54

50097

E11125

Relay

55

50731

E20305

Terminal board

56

50319

E10930

H.T. Transformer

57

50320

E40124

Flame control box

58

G06073

Support plate

59

50013

E10102-P

Switch

60

50012

E20640

Thermostat plug

61

50011

E20665

Thermostat plug cover

62

50009

E30443-1

Power cord

63

50008

E11030

Lamp

64

50441

T20355

Nozzle

65

50126

G01077

Diffuser ring

66

50048

E10215

Ignition electrode

67

50131

I31034

Brass lock nut

68

50440

I33005

Nozzle support

69

50425

G06228

Burner support disc

70

50322

G02078

H.T. Cable connect. 

71

50133

I40192

Micropipe

72

50323

E50328

Photocell

73

50336

E50327

Photoresistor support

74

50442

T20410-1

Diesel pump

75

50140

T20118

Solenoid coil

76

50141

T20117

Solenoid valve body

78

50132

I20115

Iron fitting

79

50195

E10513

Motor-pump coupling 

79

50237

E10698

Motor-pump coupling 

80

50053

T20239

Diesel pre-heated filter 

81

50144

T20241

Filter seal kit

82

50145

T20242

Filter cartridge

90

50325

E20418

Stop button protection

92

G06406-9010

Pressure switch support bracket

93

40492

E50440

Pressure switch

94

40501

I40335

Silicone pipe

95

50429

I31131

Brass hose connection

96

50433

T20442

Solenoid valve cable

97

50081

I20325-1

Fitting

98

50079

I31130

Brass hose connection

101

50453

C30323

Cable protection

102

40533

M20111

Washer 

104

E20965

Cable fastener nut 

105

E20964

Cable fastener

PARTS ORDERING INFORMATION:

PURCHASING: 

Accessories may be purchased at any HEAT 

STAR local dealer or direct from the factory 

FOR INFORMATION REGARDING SERVICE

Please call Toll-Free 866-447-2194 • www.heatstarbyenerco.

com

Our office hours are 8:00 AM – 5:00 PM, EST, Monday 

through Friday.
Please include the model number, date of purchase, and 
description of problem in all communication.

Summary of Contents for 1000ID

Page 1: ...STRUCTIONS AND OWNER S MANUAL INDIRECT FIRED PORTABLE HEATER This is a vented portable heater It uses air oxygen from the area in which it is used Adequate combustion air and ventilation must be provi...

Page 2: ...AY CONTAIN VOLATILE OR AIR BORNE COMBUSTIBLES OR PRODUCTS SUCH AS GASOLINE SOLVENTS PAINT THINNER DUST PARTI CLES OR UNKNOWN CHEMICALS WARNING THE STATE OF CALIFORNIA REQUIRES THE FOLLOWING WARNING CO...

Page 3: ...end hot air and the combus tion products into the room while those with indirect combustion are fitted with a flue to take the fumes away through the chimney Always follow local ordinances and codes w...

Page 4: ...thermostat turn the switch to ON When unit is started for the first time or is started after the oil tank has been totally emptied the flow of oil to the burner may be impaired by air in the circuit I...

Page 5: ...ority The hot air heaters with wheels must be wheeled The sus pended version which has no wheels must be transported with adequate machinery MAINTENANCE Preventive and regular maintenance will ensure...

Page 6: ...ss Replace H V transformer Flame control box defective Replace control box Photocell defective Clean or replace photocell Not enough or no fuel at all at burner Check state of motor pump plastic coupl...

Page 7: ...NG DIAGRAM 1000ID SERIES MODELS FU FUSE RV CONTROL IT TRANSFORMER H V TA ROOM THERMOSTAT LV1 OVERHEAT THERMOSTAT RE RELAYS EV1 SOLENOID VALVE 1 AP CONTROL BOX FO PHOTOCELL PA AIR PRESSURE CONTROL CO C...

Page 8: ...SERIES MODELS FU FUSE RV CONTROL IT TRANSFORMER H V TA ROOM THERMOSTAT LV1 OVERHEAT THERMOSTAT RE RELAYS EV1 SOLENOID VALVE 1 AP CONTROL BOX EV2 SOLENOID VALVE 2 FA FAN THERMOSTAT FO PHOTOCELL PA AIR...

Page 9: ...ID SERIES MODEL FU FUSE RV CONTROL IT TRANSFORMER H V TA ROOM THERMOSTAT LV1 OVERHEAT THERMOSTAT RE RELAYS EV1 SOLENOID VALVE 1 AP CONTROL BOX EV2 SOLENOID VALVE 2 FA FAN THERMOSTAT FO PHOTOCELL CN CO...

Page 10: ...41 B 09 08 A 38 92 25 24 19 06 01 02 03 40 27 28 20 22 21 18 23 35 37 34 33 26 82 05 86 10 11 13 12 17 15 18 15 14 83 84 79 78 85 89 87 88 43 51 56 61 57 58 59 07 90 93 94 95 69 91 66 67 64 63 62 68 6...

Page 11: ...60 50009 E30443 1 Power cord 61 50008 E11030 Lamp POS P N REF DESCRIPTION 62 50432 T20361 Nozzle 63 50430 I33007 Nozzle support 64 50425 G06228 Burner support disc 65 50131 I31034 Brass lock nut 66 50...

Page 12: ...30 04 A 05 09 B 47 44 20 10 07 01 02 03 45 12 23 11 66 22 37 46 36 43 06 21 25 26 24 22 27 29 31 39 35 40 42 48 72 70 71 73 64 68 67 65 69 08 80 16 14 20 14 13 81 82 92 93 94 95 32 54 59 60 61 63 49...

Page 13: ...rd POS P N ALT DESCRIPTION 54 50097 E1 1 125 Relay 55 50731 E20305 Terminal board 56 50319 E10930 H T Transformer 57 50320 E40124 Flame control box 58 G06073 Support plate 59 50013 E10102 P Switch 60...

Page 14: ...30 04 A 05 09 B 47 44 20 10 07 01 02 03 45 12 23 11 66 22 37 46 36 43 06 21 25 26 24 22 27 29 31 39 35 40 42 48 72 70 71 73 64 68 67 65 69 08 80 19 14 20 14 13 81 82 92 93 94 95 32 54 59 60 61 63 49...

Page 15: ...d 54 50097 E11125 Relay 55 50735 E20305 Terminal board 56 50556 E10930 H T Transformer 57 50320 E40124 Flame control box 58 G06073 Support plate 59 50013 E10102 P Switch 60 50012 E20640 Thermostat plu...

Page 16: ...43 51 B 49 06 20 25 26 27 28 45 43 03 47 40 41 42 39 33 32 88 91 90 89 87 85 86 92 93 94 95 80 77 84 83 82 81 68 69 70 71 100 79 77 72 76 75 74 46 30 73 07 31 99 102 103 104 105 106 109 110 106 105 1...

Page 17: ...ontrol box panel 54 50093 E20508 Fuse holder 55 40508 E10324 Fuse 57 E20319 Ground terminal board REF P N ALT DESCRIPTION 58 50731 E20305 Terminal board 59 50732 E10939 H T Transformer 60 50341 E40121...

Page 18: ...ort 122 40522 G06422 Support plate 123 40518 G06326 9005 Lifting bracket 124 40517 G06317 9005 Frame 125 40526 G06424 9005 Panel 126 40527 G06425 9005 Panel 127 40525 G06423 9005 Handle 128 40535 M300...

Page 19: ...Fuel Fired Forced Air Indirect Construction Heater Operating Instructions and Owner s Manual 19 PAGE LEFT BLANK INTENTIONALLY...

Page 20: ...purchase date and the name and address of the dealer from whom you purchased our product The foregoing is the full extent of the responsibility of the Company There are no other warranties express or...

Page 21: ...rieurement Interdisez quiconque n ayant pas lu les pr sentes instructions d assembler d allumer d ajuster ou de faire fonctionner cette fournaise INSTRUCTIONS D UTILISATION ET MANUEL DU PROPRI TAIRE F...

Page 22: ...T QUI CONTIENT OU RIS QUE DE CONTENIR DES COMBUSTIBLES VOLATILES OU EN SUSPENSION DANS L AIR OU DES PRODUITS TELS QUE DE L ESSENCE DES SOLVANTS DU DILUANT PEINTURE DES PARTICULES DE POUSSI RE OU DES P...

Page 23: ...ndirecte sont quip es d un conduit qui tire au loin les fum es travers la chemin e Respectez toujours les r glementations et les codes locaux lors de l utilisation de cette fournaise Lisez et comprene...

Page 24: ...mmutateur principal 3 0 ou r glez le thermostat ou l autre dispositif de contr le la position la plus basse La flamme s teint et le ventilateur continue de fonctionner pendant environ 90 secondes en r...

Page 25: ...nt rieur ainsi que le ventilateur avec de l air comprim v rifiez le bon raccord des connecteurs de haute tension aux lectrodes et v rifiez les c bles de haute tension Retirez l assem blage du br leur...

Page 26: ...ectrique d fectueuse Nettoyez ou remplacez la cellule photo lectrique Manque ou aucun carburant au niveau du br leur V rifiez l tat du couplage plastique de la pompe du moteur V rifiez le syst me de c...

Page 27: ...IT TRANSFORMATEUR DE HAUTE TENSION TA THERMOSTAT POUR LA PI CE LV1 THERMOSTAT DE SURCHAUFFE RE RELAIS EV1 SOUPAPE DE SOL NOIDE NO 1 AP BO TE DE CONTR LE FO CELLULE PHOTO LECTRIQUE PA CONTR LE DE LA P...

Page 28: ...ENSION TA THERMOSTAT POUR LA PI CE LV1 THERMOSTAT DE SURCHAUFFE RE RELAIS EV1 SOUPAPE DE SOL NOIDE NO 1 AP BO TE DE CONTR LE EV2 SOUPAPE DE SOL NOIDE NO 2 FA THERMOSTAT DU VENTILATEUR FO CELLULE PHOTO...

Page 29: ...N TA THERMOSTAT POUR LA PI CE LV1 THERMOSTAT DE SURCHAUFFE RE RELAIS EV1 SOUPAPE DE SOL NOIDE NO 1 AP BO TE DE CONTR LE EV2 SOUPAPE DE SOL NOIDE NO 2 FA THERMOSTAT DU VENTILATEUR FO CELLULE PHOTO LECT...

Page 30: ...09 08 A 38 92 25 24 19 06 01 02 03 40 27 28 20 22 21 18 23 35 37 34 33 26 82 05 86 10 11 13 12 17 15 18 15 14 83 84 79 78 85 89 87 88 43 51 56 61 57 58 59 07 90 93 94 95 69 91 66 67 64 63 62 68 65 97...

Page 31: ...E30443 1 Cordon d alimentation 61 50008 E11030 Lampe POS P N REF DESCRIPTION 62 50432 T20361 Buse 63 50430 I33007 Support de la buse 64 50425 G06228 Disque de support du br leur 65 50131 I31034 Contre...

Page 32: ...30 04 A 05 09 B 47 44 20 10 07 01 02 03 45 12 23 11 66 22 37 46 36 43 06 21 25 26 24 22 27 29 31 39 35 40 42 48 72 70 71 73 64 68 67 65 69 08 80 16 14 20 14 13 81 82 92 93 94 95 32 54 59 60 61 63 49...

Page 33: ...125 Relais 55 50731 E20305 Plaque bornes 56 50319 E10930 Transformateur haute tension 57 50320 E40124 Bo te de contr le de la flamme 58 G06073 Plaque de support 59 50013 E10102 P Interrupteur 60 50012...

Page 34: ...30 04 A 05 09 B 47 44 20 10 07 01 02 03 45 12 23 11 66 22 37 46 36 43 06 21 25 26 24 22 27 29 31 39 35 40 42 48 72 70 71 73 64 68 67 65 69 08 80 19 14 20 14 13 81 82 92 93 94 95 32 54 59 60 61 63 49...

Page 35: ...laque bornes 56 50556 E10930 Transformateur haute tension 57 50320 E40124 Bo te de contr le de la flamme 58 G06073 Plaque de support 59 50013 E10102 P Interrupteur 60 50012 E20640 Fiche du thermostat...

Page 36: ...43 51 B 49 06 20 25 26 27 28 45 43 03 47 40 41 42 39 33 32 88 91 90 89 87 85 86 92 93 94 95 80 77 84 83 82 81 68 69 70 71 100 79 77 72 76 75 74 46 30 73 07 31 99 102 103 104 105 106 109 110 106 105 1...

Page 37: ...54 50093 E20508 Porte fusible 55 40508 E10324 Fusible 57 E20319 Panneau de la borne de mise la terre REF P N ALT DESCRIPTION 58 50731 E20305 Plaque bornes 59 50732 E10939 Haute tension Transformateur...

Page 38: ...6 9005 Support de levage 124 40517 G06317 9005 Cadre 125 40526 G06424 9005 Panneau 126 40527 G06425 9005 Panneau 127 40525 G06423 9005 Poign e 128 40535 M30001 Ressort 129 40528 G06426 Plaque de verro...

Page 39: ...Fuel Fired Forced Air Indirect Construction Heater Operating Instructions and Owner s Manual 19 PAGE LAISS E EN BLANC INTENTIONNELLEMENT...

Page 40: ...de qui vous avez achet notre produit Ce qui pr c de est la pleine tendue de la responsabilit de l entreprise Il n existe aucune autre garantie expresse ou implicite Sp cifiquement il n existe aucune g...

Reviews: