Heatrae Sadia UTC 15 Installation And User Instructions Manual Download Page 8

8

6.6

Re-assemble the element plate assembly fitting a new sealing gasket. Note the
correct orientation of the element plate by reference to Diagram 4 below. Rewire
the unit with reference to the Wiring Diagram. Refit the insulating pad and
plastic disc to ensure the correct operation of the thermostat.

6.7

Re-commission the unit following the INSTALLATION and COMMISSIONING
instructions.

9.0 SPARE PARTS

The following comprehensive list of spare parts is available for your UTC 15 water
heater. Please refer to the Rating Label on the side of your heater before ordering to
ensure the correct spare part is obtained.

DO NOT REPLACE WITH PARTS NOT RECOMMENDED BY HEATRAE
SADIA - THIS WILL INVALIDATE YOUR GUARANTEE AND MAY
RENDER THE INSTALLATION DANGEROUS.

DESCRIPTION

CODE NO.

Element plate assembly - 3kW ............................ 95 606 922
Element plate assembly - 1.5kW......................... 95 606 927
Combined thermostat/thermal cut-out ................ 95 980 041
Indicator light ...................................................... 95 607 992
Element plate gasket ........................................... 95 611 811
Top cover moulding............................................. 95 614 246
Terminal cover c/w thermostat knob .................. 95 614 182

Diagram 4

 

Correct orientation of element plate (viewed from top of unit)

Summary of Contents for UTC 15

Page 1: ...d Water Heater HEA HEA HEA HEA HEATRAE SADIA TRAE SADIA TRAE SADIA TRAE SADIA TRAE SADIA The quality name in water heating Please read and understand these instructions before starting work Please lea...

Page 2: ...he UTC 15 vented water heater is designed to be fitted under a sink or worktop 1 2 The UTC 15 can be installed either as an Open Outlet or Cistern Fed type unit when used with the appropriate fittings...

Page 3: ...support the full weight of the unit see TECHNICAL SPECIFICATIONS and that there are no hidden services electricity gas or water below the surface of the wall 2 5 The unit should be fixed to the wall...

Page 4: ...ir of pillar taps PACK S 95 970 312 Basin hot tap PACK T 95 970 313 Basin cold tap matches Pack S 3 3 The cold water supply may be taken from the cold water mains or from a cold water feed cistern com...

Page 5: ...m internal diameter of 19mm The vent pipe must be unobstructed rise continuosly and be arranged to discharge into the cold water feed cistern DO NOT connect any pressure relief device to the vent pipe...

Page 6: ...tch on the electrical supply until the unit has been filled with water and checked for leaks 5 2 Check that all installation and electrical requirements have been met 5 3 Check that all water and elec...

Page 7: ...screws tapped jacking points are provided Remove any loose scale from the container Carefully clean off any scale from the element and thermostat pocket DO NOT clean scale from interior container wal...

Page 8: ...is available for your UTC 15 water heater Please refer to the Rating Label on the side of your heater before ordering to ensure the correct spare part is obtained DO NOT REPLACE WITH PARTS NOT RECOMME...

Page 9: ...ulty continuity and insulation 4 Check element for circuit 4 Element fault supply is on 1 Check mains water turned on 1 Cold water supply not No water flow General 2 Check for obstructions supply 2 Bl...

Page 10: ...12 3 The indicator light will be illuminated when the unit is heating 12 4 To ensure the heater continues to operate at its optimum performance it should be periodically maintained in accordance with...

Page 11: ...s not been tampered with and has been regularly main tained as detailed in these instructions 4 The unit has been used only for heating potable water The unit is not guaranteed against damage by frost...

Page 12: ...HEATING LIMITED Hurricane Way Norwich NR6 6EA Tel 01603 420100 General 01603 420330 Service Fax 01603 420149 HEA HEA HEA HEA HEATRAE SADIA TRAE SADIA TRAE SADIA TRAE SADIA TRAE SADIA The quality name...

Reviews: