8
6.6
Re-assemble the element plate assembly fitting a new sealing gasket. Note the
correct orientation of the element plate by reference to Diagram 4 below. Rewire
the unit with reference to the Wiring Diagram. Refit the insulating pad and
plastic disc to ensure the correct operation of the thermostat.
6.7
Re-commission the unit following the INSTALLATION and COMMISSIONING
instructions.
9.0 SPARE PARTS
The following comprehensive list of spare parts is available for your UTC 15 water
heater. Please refer to the Rating Label on the side of your heater before ordering to
ensure the correct spare part is obtained.
DO NOT REPLACE WITH PARTS NOT RECOMMENDED BY HEATRAE
SADIA - THIS WILL INVALIDATE YOUR GUARANTEE AND MAY
RENDER THE INSTALLATION DANGEROUS.
DESCRIPTION
CODE NO.
Element plate assembly - 3kW ............................ 95 606 922
Element plate assembly - 1.5kW......................... 95 606 927
Combined thermostat/thermal cut-out ................ 95 980 041
Indicator light ...................................................... 95 607 992
Element plate gasket ........................................... 95 611 811
Top cover moulding............................................. 95 614 246
Terminal cover c/w thermostat knob .................. 95 614 182
Diagram 4
Correct orientation of element plate (viewed from top of unit)