4.0 INSTALLATION - CISTERN FED

4.1

This method of installation must be used if the outlet is to be
connected to one or more conventional taps. It is not recommended
for supplying a shower. Individual site demands should be consid-
ered when choosing the number of outlets to be served.

4.2 A vent pipe must be connected to the outlet connection of the

heater.
The vent pipe must have a minimum internal diameter of 19mm.
The vent pipe must be unobstructed, rise continuosly and be
arranged to discharge into the cold water feed cistern.
DO NOT connect any pressure relief device to the vent pipe of
this water heater.

4.3

The cold water supply must be from a cold water feed cistern
complying with Water Byelaw 30. The maximum head pressure
must not exceed 20 metres.

4.4

It is recommended that a WBS Listed isolating valve is fitted on the
cold water supply to the heater.

4.5 The inlet must not be connected directly to the cold water mains

supply.

Diagram 3

 Typical Cistern Fed

Installation

Summary of Contents for UTC 15

Page 1: ...d Water Heater HEA HEA HEA HEA HEATRAE SADIA TRAE SADIA TRAE SADIA TRAE SADIA TRAE SADIA The quality name in water heating Please read and understand these instructions before starting work Please lea...

Page 2: ...he UTC 15 vented water heater is designed to be fitted under a sink or worktop 1 2 The UTC 15 can be installed either as an Open Outlet or Cistern Fed type unit when used with the appropriate fittings...

Page 3: ...support the full weight of the unit see TECHNICAL SPECIFICATIONS and that there are no hidden services electricity gas or water below the surface of the wall 2 5 The unit should be fixed to the wall...

Page 4: ...ir of pillar taps PACK S 95 970 312 Basin hot tap PACK T 95 970 313 Basin cold tap matches Pack S 3 3 The cold water supply may be taken from the cold water mains or from a cold water feed cistern com...

Page 5: ...m internal diameter of 19mm The vent pipe must be unobstructed rise continuosly and be arranged to discharge into the cold water feed cistern DO NOT connect any pressure relief device to the vent pipe...

Page 6: ...tch on the electrical supply until the unit has been filled with water and checked for leaks 5 2 Check that all installation and electrical requirements have been met 5 3 Check that all water and elec...

Page 7: ...screws tapped jacking points are provided Remove any loose scale from the container Carefully clean off any scale from the element and thermostat pocket DO NOT clean scale from interior container wal...

Page 8: ...is available for your UTC 15 water heater Please refer to the Rating Label on the side of your heater before ordering to ensure the correct spare part is obtained DO NOT REPLACE WITH PARTS NOT RECOMME...

Page 9: ...ulty continuity and insulation 4 Check element for circuit 4 Element fault supply is on 1 Check mains water turned on 1 Cold water supply not No water flow General 2 Check for obstructions supply 2 Bl...

Page 10: ...12 3 The indicator light will be illuminated when the unit is heating 12 4 To ensure the heater continues to operate at its optimum performance it should be periodically maintained in accordance with...

Page 11: ...s not been tampered with and has been regularly main tained as detailed in these instructions 4 The unit has been used only for heating potable water The unit is not guaranteed against damage by frost...

Page 12: ...HEATING LIMITED Hurricane Way Norwich NR6 6EA Tel 01603 420100 General 01603 420330 Service Fax 01603 420149 HEA HEA HEA HEA HEATRAE SADIA TRAE SADIA TRAE SADIA TRAE SADIA TRAE SADIA The quality name...

Reviews: