Heatrae Sadia SUPREME 150SS Fitting Instructions And User Manual Download Page 5

5

2.0 INSTALLATION - MOUNTING

2.1 The Supreme must be vertically wall mounted using the bracket

supplied.  Special precautions may be required for the protection
of children and/or infirm persons. The appliance is not intended
for   use by young children or infirm persons without supervision.
Young children should be supervised to ensure that they do not
play with the appliance.

2.2 Fig.2 details the outside dimensions of the Supreme unit.  A

template is supplied to aid positioning the heater.  It is
recommended that the unit is positioned above a draining board.
If this is not possible consideration should be given to any
spillages that may occur under the heater.  A drip tray is
available as an accessory (Heatrae Sadia Code No. 95 970
123).  The heater should be positioned at a height to suit the
items being filled (flasks, pans, cups etc.).  This is likely to
position the base of the unit 250mm above the work surface.

2.3 Sufficient room should be left around the heater for access for

maintenance and servicing.  The top should not be covered as
this will reduce the efficiency of the Supreme.

2.4 Ensure that the wall can support the full weight of the unit (see

TECHNICAL SPECIFICATIONS) and that there are no hidden
services (electricity, gas or water) below the surface of the wall.

2.5 Using the template mark the fixing positions and water and vent

entry points.  Drill and plug the fixing positions.  Fix the mounting
bracket to the wall using the two No.12 x 2” screws provided
(

confirm suitability of all screws and plugs for use with the

wall, if unsuitable due to wall type provide alternative
fixings

).

2.6 If rear entry services are to be used the necessary holes for these

should be prepared prior to hanging the unit onto its bracket.

2.7 Remove the front cover by: unscrewing the cover fixing screws

(two at the bottom), hinging the cover slightly forward and then
lifting it clear. Hang the Supreme onto the wall mounting bracket.
Secure anchor point to the wall with the No.8 x 1” long screw
(provided).

Summary of Contents for SUPREME 150SS

Page 1: ...1 Fitting Instructions and User Guide SUPREME 150SS 165SS 180SS...

Page 2: ...ion should be paid to the section headed IMPORTANT INSTALLATION POINTS Following installation and commissioning the operation of the heater should be explained to the customer and these instructions l...

Page 3: ...ents have been supplied with your Supreme heater Wall mounting bracket No 12 x 2 screws 2 off No 8 x 1 screw 1 off No 12 x 2 wall plug 2 off No 8 x 1 wall plug 1 off Template to aid in positioning the...

Page 4: ...ing main If fed from a cold water feed cistern the cistern must comply with the Water Regulations Guide clause R27 2 It should be noted that water quality may be reduced when supplied from a cistern a...

Page 5: ...e work surface 2 3 Sufficient room should be left around the heater for access for maintenance and servicing The top should not be covered as this will reduce the efficiency of the Supreme 2 4 Ensure...

Page 6: ...6 Fig 2 B A D E F 250 approx C G MODEL A B C D E F G OUTLET INLET VENT CABLE ENTRY 150SS 423 337 203 160 80 112 111 165SS 501 337 203 160 101 133 101 180SS 506 337 262 220 101 133 101 DIMENSIONS mm...

Page 7: ...isolating valve should be fitted to the cold supply to facilitate servicing the heater 4 6 Push fit connectors are supplied to allow either bottom or rear entry of services If a combination of entry p...

Page 8: ...ided unless using rear cable entry 6 5 Strip the outer sheath from the cable for a maximum of 60mm Prepare and consolidate the ends and connect the cable to the terminal block as follows BROWN or RED...

Page 9: ...calibration procedure is interrupted it will restart after a short delay but may result in the calibrated temperature being too low If this occurs switch the electrical supply OFF for several seconds...

Page 10: ...solenoid valve 8 3 The Supreme incorporates an electronic scale conditioning function which will reduce the rate of scale deposition in hard water areas However some deposits may still occur in the s...

Page 11: ...supply Unit does not heat on commissioning 1 If ON indicator not illuminated no power to unit 1 Check power supply is correctly connected and switched on and that primary cutout has not operated 2 If...

Page 12: ...ry 3 Scale build up 3 Descale unit Drips from outlet 1 Incorrect spring tension 1 Ensure tap headwork nut correctly adjusted 2 Scale debris under tap seal 2 Remove and clean as necessary 3 Damaged tap...

Page 13: ...165 180 models 95 615 007 8 Wiring harness 4way inc diodes 95 612 006 9 Wiring harness complete 95 612 013 10 Thermistor control steam 95 612 696 11 Outlet tap headwork inc handle 95 605 019 12 Outle...

Page 14: ...5 model 95 607 022 33 Inlet injector assembly 180 model 95 607 026 34 Tank 150 model 95 608 926 35 Tank 165 model 95 608 927 36 Tank 180 model 95 608 928 37 Tank drain seal 95 608 929 38 Start dry cut...

Page 15: ...OR EARTH UPPER LEVEL SENSOR LOWER LEVEL SENSOR SCALE CONDITIONING FIELD WINDING AT TEMP LED ANODE AT TEMP LED CATHODE POWER ON LED ANODE POWER ON LED CATHODE WIRING SCHEMATIC H N W L1 L2 L3 BACK PLATE...

Page 16: ...e electrical supply to the Supreme is switched on READY When fully illuminated indicates that the stored water is hot enough to use 11 5 If the store of hot water is completely withdrawn the flowrate...

Page 17: ...s been regularly maintained as detailed in the maintenance instructions 4 The unit has been used only for heating potable water The unit is not guaranteed against damage by frost or due to the build u...

Page 18: ...18 NOTES...

Page 19: ...19...

Page 20: ...Center Network 65 Buisness Park Bentley Wood Way Burnley Lancashire BB11 5ST Tel 01282 834403 www partscenter co uk Newey Eyre Specialists Products Division Please contact your local branch UK Spares...

Reviews: