INTRODUCTION

Thank you for purchasing a Heatrae Sadia Supreme water heater. This 
boiling water heater is manufactured to the highest standards and has 
been designed to meet all the latest relevant safety specifications.

This Heatrae Sadia water heater must be installed (sections 1-6, p4-9), 
commissioned (section 7, p10) and maintained (sections 8-9, p11-13) 
by a competent person. Please read and understand these instructions 
prior to installing your Heatrae Sadia water heater. Following installation 
and commissioning the operation of the heater should be explained to 
the user (section 11, p16) and these instructions left with them for future 
reference.

This appliance can be used by children aged from 8 years 
and above if they have been given supervision or instruction 
concerning use of the appliance in a safe way and if they 
understand the hazards involved. Cleaning and user 
maintenance shall not be made by children unless they are 
older than 8 and supervised. Keep the appliance and its cord 
out of reach of children aged less than 8 years.

Appliances can be used by persons with reduced physical. 
sensory or mental capabilities or lack of experience and 
knowledge if they have been given supervision or instruction 
concerning use of the appliance in a safe way and understand 
the hazards involved.

Children shall not play with the appliance.

This appliance is intended to be used in household and 
similar applications such as:
- staff kitchen areas in shops, offices and other working      
  environments
- farm houses
- by clients in hotels, motels and other residential type  
  environments
- bed and breakfast type environments

Summary of Contents for SUPREME 150

Page 1: ...Supreme 150SS 165SS 180SS Fitting Instructions and User Guide...

Page 2: ...and above if they have been given supervision or instruction concerning use of the appliance in a safe way and if they understand the hazards involved Cleaning and user maintenance shall not be made b...

Page 3: ...bow push fit connector TECHNICAL SPECIFICATIONS Electrical rating 2 3 2 5 kW 230 240V Nominal capacities Model 150SS 2 5 litres Model 165SS 5 0 litres Model 180SS 7 5 litres Weight full Model 150SS 12...

Page 4: ...istern must comply with the Water Regulations Guide clause R27 2 It should be noted that water quality may be reduced when supplied from a cistern and additional forms of water pre treatment may be ne...

Page 5: ...heater for access for maintenance and servicing The top should not be covered as this will reduce the efficiency of the Supreme 2 4 Ensure that the wall can support the full weight of the unit see TEC...

Page 6: ...MENSIONS B A D E F 250 approx C G MODEL A B C D E F G OUTLET INLET VENT CABLE ENTRY 150SS 423 337 203 160 80 112 111 165SS 501 337 203 160 101 133 101 180SS 506 337 262 220 101 133 101 DIMENSIONS mm F...

Page 7: ...et pipe run is horizontal and beneath the unit ensure it does not prevent access to the case screws 4 4 Connect the inlet pipe to the push fit connector ensuring it is fully pushed home 28mm engagemen...

Page 8: ...connection 5 3 Connect the vent pipe to the push fit connector ensuring it is pushed fully home 28mm engagement Refer to the vent pipe requirements detailed in IMPORTANT INSTALLATION POINTS p4 If a b...

Page 9: ...switching the unit off It is recommended that this is done automatically by incorporating a suitable timeswitch in the supply to the unit The use of an accessory no 95 970 124 is recommended The times...

Page 10: ...inated If for any reason the calibration procedure is interrupted it will restart after a short delay but may result in the calibrated temperature being too low If this occurs switch the electrical su...

Page 11: ...le conditioning function which will reduce the rate of scale deposition in hard water areas However some deposits may still occur in the storage tank these should be periodically removed 8 2 The amoun...

Page 12: ...system 3 Check connections to electronic control Replace if necessary 4 Increase inlet pressure Steam from vent pipe and primary cutout operates 1 Control thermistor fault open circuit 2 Electronic c...

Page 13: ...scale detected The unit requires cleaning and de scaling Power light gives 2 flashes and the unit shuts down There is no water Check water supply to the unit is avail able and turned on Power light gi...

Page 14: ...4 005 12 Steam condenser assy 2 5ltr Model 95 607 015 Steam condenser assy 5 0ltr Model 95 607 016 Steam condenser assy 7 5ltr Model 95 607 018 13 Condenser sealing gasket 2 5ltr Model 95 611 817 Cond...

Page 15: ...15 11 4 23 19 3 12 13 14 6 7 8 9 10 18 14 16 15 21 14 2 1 5 29...

Page 16: ...g rate of the heater This slow flowrate allows the incoming water to be instantly reheated it does not indicate a fault with the water heater 11 6 If the Supreme is not used for a few days the water m...

Page 17: ...been regularly maintained as detailed in the maintenance instructions 4 The unit has been used only for heating potable water The unit is warranty does not cover against damage by frost or due to the...

Page 18: ...18 Notes...

Page 19: ...19 Notes...

Page 20: ...ate responsibility and sustainability charters and reduce our printed material we encourage you to download product brochures from our website In designing these files we have taken into account the n...

Reviews: