![Heatrae Sadia STREAMLINE OVERSINK 95010281 Fitting Instructions And User Manual Download Page 6](http://html1.mh-extra.com/html/heatrae-sadia/streamline-oversink-95010281/streamline-oversink-95010281_fitting-instructions-and-user-manual_2117711006.webp)
6
3.0 INSTALLATION
WARNING: THE STREAMLINE IS AN OPEN OUTLET WATER HEATER. THE
OUTLET OF THE STREAMLINE ACTS AS A VENT AND MUST ONLY BE
CONNECTED TO HEATRAE SADIA VENTED TAPS OR SPOUTS. THESE
FITTINGS MUST NEVER BE BLOCKED, RESTRICTED OR MODIFIED, IN
ANY WAY.
3.1 GENERAL
The Streamline Oversink Water Heater must be vertically wall mounted using
the wall bracket supplied. The water inlet connection must always be at the
bottom of the Streamline Oversink Water Heater on the right side.
3.2 LOCATION
Ensure that the wall can support the full weight of the Streamline and that
1.
there are no hidden services (electricity, gas or water) below the surface
of the wall.
DO NOT install the Streamline where it may freeze.
2.
Allow 50mm access above and 100mm below for maintenance.
3.
NOTE: National Wiring Rules may contain restrictions concerning the
installation of the Streamline in bathrooms.
FIGURE 03 - FRONT COVER
COVER SCREWS
HINGE AT TOP