Heatrae Sadia STREAMLINE OVERSINK 95010281 Fitting Instructions And User Manual Download Page 3

3

1.0 INTRODUCTION

Thank you for purchasing a Heatrae Sadia Streamline Oversink Vented Water 

Heater. The Streamline is manufactured in the UK to the highest standards and 

has been designed to meet all the latest relevant safety specifications.

1.1 IMPORTANT POINTS

The Streamline must be installed and commissioned by a competent person. 

Please read and understand these instructions before installing the Streamline.  

Following  installation  and  commissioning,  the  operation  of  the  Streamline 

should be explained to the user and these instructions left with them for future 

reference.

The Streamline is not intended for use by persons (including children) with 

reduced physical, sensory or mental capabilities, or lack of experience and 

knowledge, unless they have been given supervision or instruction concerning 

the use of the appliance by a person responsible for their safety.

Children  should  be  supervised  to  ensure  they  do  not  play  with  the 

Streamline.

1.2 PACK CONTENTS

Before commencing installation check that all the following components have 

been supplied with your Streamline Oversink Water Heater:

•  Wall Mounting Bracket

•  Fixing Plugs and Screws

•  Spout

Thermostat Knob

• 

Control Knob

• 

Control Knob Extension

• 

Flow Restrictor

• 

Summary of Contents for STREAMLINE OVERSINK 95010281

Page 1: ...1 STREAMLINE OVERSINK Fitting Instructions and User Guide...

Page 2: ...CATIONS 4 3 0 INSTALLATION 6 4 0 COMMISSIONING 10 5 0 EXPLANATION TO USER 11 6 0 MAINTENANCE 12 7 0 FAULT FINDING 14 8 0 SPARE PARTS 15 9 0 GUARANTEE 17 10 0 ENVIRONMENTAL INFORMATION 17 11 0 COMMISSI...

Page 3: ...o the user and these instructions left with them for future reference The Streamline is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack...

Page 4: ...g full Weight 10 Litre 4 0Kg empty 14 0Kg full Enclosure rated IPX4 Operating Pressure 0 MPa 0 bar TABLE 01 PERFORMANCE DATA MODEL HEAT UP MINUTES HEAT LOSS kWhr 24hr 7 Litre 1kW 25 0 5 7 Litre 3kW 9...

Page 5: ...5 A 346 R276 4 32 5 50 18 5 70 290 471 74 450 500 213 FIGURE 02 DIMENSIONS IN mm THIRD FIXING HOLE DIMENSION A 7 LITRE 10 LITRE 278 178 17...

Page 6: ...ied The water inlet connection must always be at the bottom of the Streamline Oversink Water Heater on the right side 3 2 LOCATION Ensure that the wall can support the full weight of the Streamline an...

Page 7: ...d fix securely with the 6 third smallest fixing screw provided 3 4 PLUMBING Plumb the Streamline direct to the cold water main using 15mm diameter 1 copper or plastic pipe Water pressure should be no...

Page 8: ...re the spout clamp ribs engage with the spout 4 and hold it securely in place Tighten the 1 2 BSP nut 5 Ensure the grommet is re seated snapped to the backplate 6 Fit the spout front to the spout body...

Page 9: ...eparation of at least 3mm 2 in each pole must be incorporated in the supply The Streamline must be fitted with a 3 core 1 5mm 3 2 flexible cable The cable must be fitted through the cable gland and co...

Page 10: ...trol knob is engaged with the 8 control valve extension and snaps to the front cover Set the temperature 9 The maximum setting is 70 C and the minimum is 5 C Rotate the thermostat knob clockwise to in...

Page 11: ...ausing 3 the tap to drip This is normal and is not a fault with the Streamline 5 2 SYSTEM MALFUNCTION Explain how to isolate electrical and water supplies in case of a fault 1 Explain that a qualified...

Page 12: ...operation 6 1 DRAIN THE STREAMLINE Ensure the water and power supplies to the Streamline are switched off 1 and the water is cold Remove the thermostat knob use a medium sized flat bladed screwdriver...

Page 13: ...ect alignment Refit the locknut rotate the locknut clockwise until the EPA is held 7 securely in place NOTE When tight one of the locknut spokes should be at 9 O Clock and central to the live and neut...

Page 14: ...ed on Check supply and turn on Insufficient mains pressure Check supply Blockage in tap Clean tap No hot water No water in heater Fill water heater Cut out has operated Reset cut out Faulty thermostat...

Page 15: ...ck of 10 95611018 4 EPA Locknut 95607617 5 7 Litre Inner Container 95608028 6 10 Litre Inner Container 95608029 7 Drain Plug with O ring 95608929 8 Drain Plug O Ring pack of 10 95611017 9 Thermostat 9...

Page 16: ...16 FIGURE 15 SPARE PARTS 9 10 11 12 5 3 1 4 18 7 19 15 17...

Page 17: ...pered with and has been regularly 3 maintained The Streamline has been used only for heating potable water 4 The Streamline is not guaranteed against damage by frost or due to the build up of scale Pl...

Page 18: ...er Electrical ________________________________________ Contact Details ____________________________________________ Competency Scheme ID Number _________________________ Comments _____________________...

Page 19: ..._____________ ________________________________________________ ________________________________________________ Service Date _______________________________________________ Engineer __________________...

Page 20: ...s 9 10 Hexagon Business Centre Springfield Road Hayes Middlesex UB40 0TY Tel 020 8606 3567 Parts Center Tel 0845 2709800 www partscenter co uk Newey Eyre Specialist Products Division Please contact yo...

Reviews: