2.0 GENERAL REQUIREMENTS

2.1 COMPONENTS SUPPLIED

1. Premier Plus unvented solar water heater incorporating immersion heater(s) and thermal controls

2. Factory fitted temperature/pressure relief valve 

3. Cold water combination valve.   

4. Expansion vessel and mounting bracket. 

5. Tundish.

6. Motorized valve (indirect models only).

7. Compression nuts and olives

8. Immersion heater key spanner

2.2 SITING THE UNIT

The Premier Plus Solar must be installed vertically. Although location is not critical, the following points should be 

considered:

•  The Premier Plus Solar should be sited to ensure minimum dead leg distances, particularly to the  

 

 

point of most frequent use.

•  Avoid siting where extreme cold temperatures will be experienced. All exposed pipe-work should be  

 

 insulated.

•  The discharge pipe-work from the safety valves must have minimum fall of 1:200 from the unit and terminate  

 

in a safe and visible position.

•  Access to associated controls and immersion heaters should be possible to allow for periodic servicing and  

 maintenance.

•  Ensure that the base chosen for the Premier Plus Solar is level and capable of permanently supporting    

the weight when full of water (see Table 2)

2.3 OUTLET/TERMINAL FITTINGS   (TAPS, ETC.)

The Premier Plus Solar can be used with most types of terminal fittings. It is advantageous in many mixer showers to 

have balanced hot and cold water supplies. In these instances a balanced pressure cold water connection should be 

placed between the cold water combination valve and the Premier Plus water heater. Outlets situated higher than 

the PremierPlus Solar will give outlet pressures lower than that at the heater, a 10m height difference will result in 

a 1 bar pressure reduction at the outlet.

2.4 LIMITATIONS

The Premier Plus unvented solar water heater should not be used in association with any of the following:

•  Solid fuel boilers or any other boiler in which the energy input is not under effective thermostatic control  

 

unless additional and appropriate safety measures are installed.

•  Ascending spray type bidets or any other class 1 back syphonage risk requiring that a type A air gap be    

 employed.

•  Steam heating plants unless additional and appropriate safety devices are installed.

•  Situations where maintenance is likely to be neglected or safety devices tampered with.

•  Water supplies that have either inadequate pressure or where the supply may be intermittent.

•  Situations where it is not possible to safely pipe away any discharge from the safety valves.

•  In areas where the water consistently contains a high proportion of solids, e.g. suspended matter that could  

 

block the strainer, unless adequate filtration can be ensured.

The PremierPlus solar cylinder is to be used for the storage of wholesum water (max 250mg/l Chloride)

Summary of Contents for PremierPlus PES170D

Page 1: ...PremierPlus Solar Unvented Hot Water Cylinder Installation and User Manual SOLAR D SOLAR INDIRECT DIRECT...

Page 2: ...nt for their needs that it is installed commissioned and serviced in accordance with the manufacturer s instructions by competent persons and that it meets the requirements of the appropriate Building...

Page 3: ...SUPERVISION WARNING Do not switch on if there is a possibility that the water in the heater is frozen OPERATIONAL SUMMARY Indirect models in conformance with BS EN 12897 2006 Maximum mains water suppl...

Page 4: ...nts of the CE marking directive and is KIWA approved to show compli ance with Building Regulations Section G3 The following instructions are offered as a guide to installation which must be carried ou...

Page 5: ...ngs It is advantageous in many mixer showers to have balanced hot and cold water supplies In these instances a balanced pressure cold water connection should be placed between the cold water combinati...

Page 6: ...pansion vessel should allow access to recharge the pres sure as and when necessary this can be done using a normal car foot pump It is recommended that the expansion vessel is adequately supported An...

Page 7: ...LET 10 SOLAR CONTROL HOUSING A B C D E F TYPE DIMENSIONS mm AUXILLARY VOLUME litres AUXILLARY COIL SURFACE AREA sq m RATING kW HOT WATER DRAW OFF Litres to 40 C HEATING TIME DIRECT MINS SOLAR SURFACE...

Page 8: ...at is used by the safety devices the manifold should be factory fitted as part of the hot water storage system unit or package Tundish 3 54 The tundish should be vertical located in the same space as...

Page 9: ...revent contact whilst maintaining visibility and d discharges at high level e g into a metal hopper and metal downpipe with the end of the discharge pipe clearly visible or onto a roof capable of with...

Page 10: ...ee Building Regulation G3 section 3 56 Table 4 and worked example Valve outlet size Minimum size of discharge pipe D1 Minimum size of discharge pipe D2 from tundish Maximum resistance allowed expresse...

Page 11: ...le Fig 6 Direct Electrical connections schematic THERMAL CUT OUT RESET BUTTON SPINDLE POSITIONS MINIMUM TEMP 10 C MAXIMUM TEMP 72 C APPROX 60 C ROTATE SPINDLE CLOCKWISE FOR TEMPERATURE INCREASE AND CO...

Page 12: ...CUT OUT PROBE CONTROL ASSEMBLY POWER SUPPLY TO SOLAR CONTROLLER L N E SOLAR CONTROLLER L N 1 2 3 Control Housing Details Element Connections 1 5mm 3 Core HOFR sheathed cable Indirect control wiring F...

Page 13: ...ar circulation is stopped 5 0 INSTALLATION DIRECT UNITS 5 1 PLUMBING CONNECTIONS Direct units require the following pipework connections Cold water supply to and from inlet controls Outlet to hot wate...

Page 14: ...located under the terminal cover mounted on the side of the unit The supply cable s must be routed through the cable grip s in the terminal housing DISCONNECT FROM MAINS SUPPLY BEFORE REMOVING ANY CO...

Page 15: ...PERATION OF THEIR PRODUCTS WITHIN THE SYSTEM KEY Bl BLUE Br BROWN G GREY O ORANGE GY GREEN YELLOW DHW DOMESTIC HOT WATER HTG HEATING DHW OFF 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Bl Br G O GY L N N L...

Page 16: ...n be adjusted by inserting a flat bladed screwdriver in the adjustment knob on top of the immersion heater thermostat and rotating The adjustment range on the spindle represents a temperature range of...

Page 17: ...nscrew immersion heater backnut s and remove immersion heater from the unit A key spanner is supplied with the PremierPlus solar unit for easy removal tightening of the immersion heater s Over time th...

Page 18: ...leaks The heating source immersion heater s boiler or solar primary circuit can then be switched on 8 7 BENCHMARKTM LOG BOOK On completion of any maintenance or service of the Premier Plus the Benchm...

Page 19: ...hermostat and thermal cut out These controls must be wired in series with the 2 port motorised zone valve supplied to interupt the flow of primary water around the heat exchanger coil when the control...

Page 20: ...hen drawing water from the unit SPARE PARTS A full range of spare parts are available for the PremierPlus cylinder range See Table 6 Page 22 Refer to the technical data label on the unit to identify t...

Page 21: ...tly Check wiring and or plumbing connections to motorised valve Water discharges from expansion valve INTERMITTENTLY Expansion vessel charge pressure has reduced below 3 5bar or set to high See Mainte...

Page 22: ...odels 95 607 863 13 Expansion vessel 18 litre 170 and 210 litre models 95 607 864 14 Expansion vessel 24 litre 250 and 300 litre models 95 607 612 15 Blanking plate assembly 95 605 881 16 Nut olive pa...

Page 23: ...23 18 4 23 20 3 24 17 19 22 1 25 Fig 13 Indirect Solar...

Page 24: ...24 4 3 17 22 20 2 1 17 24 23 25 Fig 14 Direct Solar...

Page 25: ...t The BenchmarkTM Commissioning Checklist Service Record included in this product Guide has been completed Regular maintenance has been carried out by a competent person in accordance with the require...

Page 26: ...26...

Page 27: ...27...

Page 28: ...te responsibility and sustainability charters and reduce our printed material we encourage you to download product brochures from our website In designing these files we have taken into account the ne...

Reviews: