Heatrae Sadia HRU ECO 4 User Manual Download Page 27

7. Declarations

EG-Verklaring van overeenstemming | Déclaration de conformité CE |

EG-Konformitätserklärung | EC Declaration of Conformity

Heatrae Sadia

Hurricane Way

Norwich NR6 6EA

United Kingdom

Verklaart dat het product | Déclare que le produit |
Erklärt dass das Produkt | Declares that the product:

-

Ventilation unit with heat recovery

HRU ECO 4-Apartment

-

Ventilation unit with heat recovery

HRU ECO 4 House

Voldoet aan de bepalingen gesteld in de richtlijnen |
Répond aux exigences des directives |
Entspricht den Anforderungen in den Richtlinien |
Complies with the requirements stated in the directives:

-

Low Voltage Directive 2014/35/EU

-

Electromagnetic Compatibility (EMC) Directive

2014/30/EU

-

Directive 2009/125/EC establishing a framework

for the setting of ecodesign requirements for

energy-related products

-

Directive 2010/30/EU on the indication by

labelling and standard product information of

the consumption of energy and other resources

by energy-related products.

-

Commission Regulation (EU) No 1253/2014 of 7

July 2014 implementing Directive 2009/125/EC

of the European Parliament and of the Council

with regard to ecodesign requirements for

ventilation units

-

Commission Delegated Regulation (EU) No

1254/2014 of 11 July 2014 supplementing

Directive 2010/30/EU of the European

Parliament and of the Council with regard to

energy labelling of residential ventilation units

Voldoet aan de geharmoniseerde Europese normen |
Répond aux normes Européennes harmonisées |
Entspricht den harmonisierten europäischen Normen |
Complies with the harmonized European standard:

EN 60335-1:2012 | EN 60335-2-80:2003/A1:2004

EN 60335-2-80:2003/A2:2009

EN 60730-1:2012

EN 55014-1:2007 | EN 55014-1:2007/C1:2009

EN 55014-1:2007/A1:2009 | EN 55014-1:2007/A2:2010

EN 55014-2:1998 | EN 55014-2:1998/C1:1998

EN 55014-2:1998/A1:2002 | EN 55014-2:1998/IS1:2007

EN 55014-2:1998/A2:2008

EN 61000-3-2:2006/A1:2009 | EN 61000-3-2:2006/

A2:2009

EN 61000-3-3:2013 | EN 61000-6-1:2007

EN 61000-6-3:2007/A1:2011 | EN 61000-6-3:2007/AC:

2012

Voldoet aan de volgende nationale en internationale technische
normen en specificaties |
Répond aux normes techniques nationales et internationales et aux
spécifications nationales et internationales |
Entspricht den folgenden nationalen und internationalen
technischen Normen und Spezifikationen |
Complies with the following national and international technical
standards and specifications:

-

Directive on the restriction of the use of certain

hazardous substances in electrical and electronic

equipment 2011/65/EU

Norwich, 1 July 2017.

27

Summary of Contents for HRU ECO 4

Page 1: ...HRU ECO 4 User manual...

Page 2: ...Translation of the original document...

Page 3: ...em or surrounding area Note Instructions important for the installation functioning operation or maintenance of the product Failure to observe these instructions can result in minor damage to the prod...

Page 4: ...fiche information 12 2 8 Accessories 13 2 9 Recycling 13 3 Operation 14 3 1 Ventilation speeds 14 3 2 Devices 15 3 3 Sensors 15 3 4 Pairing and unpairing wireless devices and sensors 15 4 Inspection...

Page 5: ...experience knowledge if under supervision or after having received instructions regarding safe use and if they are aware of the product and or system hazards Cleaning and maintenance by the user may...

Page 6: ...pect the product regularly for faults In the event of faults switch the product off and contact your installer or Heatrae Sadia Customer Service immediately Switch the product off if The product is no...

Page 7: ...ECO 4 ventilation system from Heatrae Sadia is an example of these advanced appliances The HRU ECO 4 is a balanced ventilation system with heat recovery The ventilation unit is equipped with two fans...

Page 8: ...rgies who are sensitive to this During the product s lifetime the filters will become dirty which reduces the capacity of the ventilation unit It is therefore essential that the filters are cleaned as...

Page 9: ...nergy efficient manner When the the CO2 level has fallen sufficiently the capacity of the ventilation unit is automatically decreased Tip It is possible to place several wireless sensors and controls...

Page 10: ...2x s Bypass mode Lit Normal operation Pattern Function Red Orange Blinks 1x s Blinks 1x s Exhaust fan fault Blinks 1x s Blinks 2x s Supply fan fault Blinks 2x s Blinks 2x s Exhaust temperature sensor...

Page 11: ...ring forced drying Good ventilation and air circulation are essential during the drying process During the first year keep furniture approximately 5 cm away from the walls to allow the moisture to esc...

Page 12: ...Pmax W 154 Sound power level LWA dB 52 Reference flow rate qref m3 s 0 069 Reference pressure difference Pref Pa 50 Specific power input SPI W m3 h 0 255 Ventilation control Manual control no DCV Con...

Page 13: ...n how to do so The product s packaging can be recycled These materials should be disposed of in a responsible manner in accordance with government regulations As a reminder of the need to dispose of b...

Page 14: ...te The timer can be stopped at any time by pressing the button for low speed high speed or automatic mode Auto Night Auto Night raises the minimum ventilation speed to ensure sufficient ventilation du...

Page 15: ...on page 15 3 4 Pairing and unpairing wireless devices and sensors 3 4 1 Pairing wireless devices Pairing a wireless control switch should be done in the vicinity of the ventilation unit a Switch off p...

Page 16: ...he ventilation unit is switched on For more information consult the documentation provided with the relevant sensor The sensor is paired and the ventilation unit briefly changes speed to confirm the p...

Page 17: ...heck for soiling and leakage 6 months 1 year Motor module Check for soiling imbalance 1 year Bypass valve Frost valve Check functioning and for soiling 1 year Heat exchanger Check for soiling 1 year A...

Page 18: ...he filters as follows a Disconnect power to the ventilation unit b Remove both filter holders c Visually inspect the filters for soiling If the filters are dirty they must be cleaned or replaced d Cle...

Page 19: ...me time Warning HRU ECO 4 should always be fitted with the appropriate filters Without filters the appliance can be irreparably damaged Note The dirty filter indication cannot be reset via the control...

Page 20: ...ubber gaskets b Fully immerse the valves in a solution of a mild cleaning agent such as washing up liquid or all purpose cleaner If necessary the valves can be cleaned in a dishwasher c Wipe off the v...

Page 21: ...an for soiling and clean it if necessary Check the fan for defects and replace it if necessary The status LED on the ventilation unit blinks once red and twice orange Cause Solution a The ventilation...

Page 22: ...he unit will automatically return to normal operation Neither fan is rotating Cause Solution a The ventilation unit s plug is not plugged into a power socket Insert the plug into a power socket b The...

Page 23: ...connected to the unit Check the connections and ensure that fixed ducts are clamped to the wall ceiling or floor e The bypass valve is blocked rattling noise The bypass valve strikes the stop during t...

Page 24: ...nect the switch wires correctly see wiring diagram d The ventilation unit PCB is faulty Replace the PCB and carry out the commissioning procedure again The ventilation unit is leaking water Cause Solu...

Page 25: ...g supplied to the dwelling Cause Solution a The filter in the extraction outlet is blocked Clean or replace the filter in the air outlet b The air valves are not correctly adjusted Put the ventilation...

Page 26: ...claimer This warranty does not apply to Disassembly and assembly costs Faults which are caused by incorrect treatment Negligence or accident Faults that have been caused by repairs by third parties wi...

Page 27: ...mmission Delegated Regulation EU No 1254 2014 of 11 July 2014 supplementing Directive 2010 30 EU of the European Parliament and of the Council with regard to energy labelling of residential ventilatio...

Page 28: ...HEATRAE SADIA HEATING Hurricane Way Norwich NR6 6EA www heatraesadia com SERVICE 44 0 344 871 1535 EMAIL customer support heatraesadia com 01 02504 002 ID 2018 02 07 1426...