10
PIPE ENTRY
5.8 Plumbing entry can be from the rear (preferred) or from the bottom.
The backplate has a cut-out position to suit 15mm pipe.When opting
for bottom entry make cut-out before fitting backplate to the wall - see
Figure 6.
6.0 FITTING INSTRUCTIONS
6.1
TURN OFF
water and electrical supply.
6.2 The appliance is designed for bottom and rear entries of water and
electric cable.
It is advised to use the rear entry (when it is
possible), in order to obtain a neater installation.
6.3 Unscrew the retaining screws and lift the cover from the back plate -
see Figure 7.
6.4 Fit the outlet spout -
DO NOT
over tighten, finger tight will be
sufficient - see Figure 8.
6.5 After choosing the correct site for the handwash, use the backplate as
a template and mark the two fixing holes - see 5.1 to 5.7.
BEWARE OF CABLES AND PIPES WHICH MAY BE BURIED IN
THE WALL.
6.6 Drill holes using a 6.5mm diameter masonry drill.
6.7 Use plugs to suit the wall and use the fixing screws supplied.
Figure 7 Removing Cover
Make cut-out
using sharp knife
Figure 6 Plumbing cut-out
Figure 8 Fitting outlet spout
'O' rings
Plastic nut
(finger tight only)
Outlet pipe
Cable
Clamp
Inlet water
connection
Terminal
Block
Rear entry access
area for electricity and
inlet water supply
Figure 9 Unit layout - Dimensions (mm)
86
19
.5
19
6.
5
74
29
23
5
151