The outlet fitting is located on the underside of the heater and is threaded
3/4.BSP Female on the FBM25, 50 and 75, and 1”BSP Female on the
FBM125.

A Drain fitting is provided and is located on the element plate assembly under
the terminal cover. Ensure the electrical supply is disconnected before
removing the terminal cover and draining the heater.

To fill the heater the cold water supply should be turned on and a hot outlet
supplied by the heater opened. When water flows from the outlet, turn off and
allow cistern tank to fill. Adjust the float such that the Float Valve closes

when the water level in the cistern corresponds with the marked water level
line. After adjustment replace the cistern cover and secure using the cover
screw(s) provided.

ELECTRICAL CONNECTION

WARNING This appliance must be earthed. Installation must conform
with current IEE Wiring Regulations. It should be connected to a 230/
240V a.c. electrical supply via a double pole isolating switch with a
minimum 3mm contact separation in both poles. The supply cable
must have a minimum cross sectional area of 1.5mm

2

 for each

element. NOTE 6kW units have two elements.

ELEMENT
3kW  AT 240V

L

N

EARTH POST

THERMOSTAT

THERMAL 
CUTOUT

230/240V ac SUPPLY
VIA DOUBLE POLE 
ISOLATING SWITCH

Fig 2. Schematic Wiring Diagram 3kW units

Summary of Contents for FBM series

Page 1: ...1 FBM RANGE Fitting Instructions and User Guide...

Page 2: ...able of supporting the full weight of the water heater see chart Mount the water heater as higher as possible the top of the water heater must be at least 1 2 m 4 feet above the highest draw off point...

Page 3: ...lts mark top two fixing positions Remove heater drill and plug these positions Replace heater onto bottom fixing bolts secure by screwing in top fixing bolts Tighten bottom fixing bolts FBM25 19 59 68...

Page 4: ...valve body and cistern wall secure by tightening backnut on outside of heater The Overflow fitting can also be mounted on the left or right by drilling the appropriate position as for the Float valve...

Page 5: ...at such that the Float Valve closes when the water level in the cistern corresponds with the marked water level line After adjustment replace the cistern cover and secure using the cover screw s provi...

Page 6: ...nation marked L Neutral coloured Blue or Black to ELEMENT termination marked N Earth coloured Green Yellow or Green to EARTH POST marked If Twin and Earth cable is used the bare Earth conductor must b...

Page 7: ...Over temperature Cut out is adjustable and should be set approx 15 C above the control thermostat setting The maximum Over temperature Cut out setting should be 85 C The 6kW units have two fixed temp...

Page 8: ...d for the storage of category 1 or 2 water It has not been tampered with or been subjected to misuse or neglect Within 60 days of installation the user completes and returns the certificate supplied a...

Reviews: