NOTICE TO INSTALLER

These water heater have a built in cold water feed cistern and float valve and
can supply a number of hot water outlets. As the hot water flows by gravity
the water heater must be mounted higher than the taps they serve. Ideally
the heater should be fitted close to the point where hot water is required
most frequently. pipe runs sholud be kept to a minimum.

The installation must be carried out in accordance with the relevant
requirements of:

     •

The appropriate Building Regulations either The Building
Regulations, The Building Regulations (Scotland) or Building
Regulations (Northern Ireland).

     •

The Water Fittings Regulations or Water Byelaws in Scotland.

SITING THE HEATER

The FBM Range is suitable for wall mounting only. Ensure that the wall is
capable of supporting the full weight of the water heater (see chart).

Mount the water heater as higher as possible, the top of the water heater
must be at least 1.2 m (4 feet) above the highest draw off point to ensure a
reasonable pressure, allowing 225mm (9”) above the heater for access to the
cistern tank. DO NOT  install in a position where the heater is liable to be
subjected frost conditions.
Refer to Fig. 1 and Dimension Chart for fixing centres. A template is also
supplied with the FBM25 and 50.

FBM 25 and 50:

Using the template provided, mark off fixing positions of the two top holes

(ensuring that they are level).

Drill and plug these positions.

Screw in fixing bolts leaving underside of head 12mm from wall.

Hang heater onto fixing bolts ensuring they engage in keyhole slots.

Mark bottom centre fixing (access is easier if terminal cover is removed).

Remove heater, drill and plug this position.

Replace heater onto keyhole slots, secure by screwing in bottom fixing
bolt.

Summary of Contents for FBM series

Page 1: ...1 FBM RANGE Fitting Instructions and User Guide...

Page 2: ...able of supporting the full weight of the water heater see chart Mount the water heater as higher as possible the top of the water heater must be at least 1 2 m 4 feet above the highest draw off point...

Page 3: ...lts mark top two fixing positions Remove heater drill and plug these positions Replace heater onto bottom fixing bolts secure by screwing in top fixing bolts Tighten bottom fixing bolts FBM25 19 59 68...

Page 4: ...valve body and cistern wall secure by tightening backnut on outside of heater The Overflow fitting can also be mounted on the left or right by drilling the appropriate position as for the Float valve...

Page 5: ...at such that the Float Valve closes when the water level in the cistern corresponds with the marked water level line After adjustment replace the cistern cover and secure using the cover screw s provi...

Page 6: ...nation marked L Neutral coloured Blue or Black to ELEMENT termination marked N Earth coloured Green Yellow or Green to EARTH POST marked If Twin and Earth cable is used the bare Earth conductor must b...

Page 7: ...Over temperature Cut out is adjustable and should be set approx 15 C above the control thermostat setting The maximum Over temperature Cut out setting should be 85 C The 6kW units have two fixed temp...

Page 8: ...d for the storage of category 1 or 2 water It has not been tampered with or been subjected to misuse or neglect Within 60 days of installation the user completes and returns the certificate supplied a...