46
4.8.6 PROGRAMMING MENU
The programming menu is used to the check parameters which may be changed.
To check / alter a parameter:
Select the programming sub menu as shown in section 4.8.4
•
Press UP or DOWN to scroll to the required parameter.
•
Press RIGHT to select the parameter. The icon will flash.
•
Press UP to increase the parameter value.
•
Press DOWN to decrease the parameter value.
•
Press RIGHT and the OK icon will flash.
•
Press RIGHT to confirm the parameter setting.
•
4.8.7 MANUAL OPERATION MENU
The manual operation menu allows the solar sytem to be operated by hand for test / service
purposes.
NOTE: During manual operation there is no auotmatic regulation of the system.
To manually operate the solar pump:
Select the manual operation sub menu as shown in section 4.8.4
•
Press UP or DOWN to switch the pump ON or OFF.
•
Press RIGHT to confirm the setting.
•
NOTE: Automatic regulation will be re actived after 8 hours.
FIGURE 31: PROGRAMMING MENU ICONS
DESCRIPTION
FACTORY SET
65°C
7K
3K
100%
RANGE
15 - 95°C
3 - 40 K
2 - 25 K
30 - 100%
INDICATION
01°C max.
dT max 7 K
dT min 3 K
min 100
MAXIMUM STORAGE TANK
TEMPERATURE
STORAGE TANK SWITCH ON
DIFFERENCE (dTon)
STORAGE TANK SWITCH OFF
DIFFERENCE (dToff)
PUMP SPEED CONTROL
(100% = SPEED CONTORL OFF )
2
FIGURE 32: MANUAL OPERATION MENU ICONS
DESCRIPTION
RANGE
1 = ON
0 = OFF
INDICATION
SWITCH SOLAR CIRCULATION PUMP ON / OFF