PARAMETER CHECKING AND ADJUSTMENT
Parameter list
Some parameters can be checked and adjusted by the controller. Below is the parameter list.
No
Parameter Name
Range
Default
Remark
0
Memory function if power off
0
(
no
)
\1
(
yes
)
1
Adjustable
1
Timer cycle (every day or once)
0
(
once
)
\1
(
every day
)
1
Adjustable
2
X (Temp difference btw. inlet water
temp and setting water temp to start
compressor)
2-10
℃
3
Adjustable
3
Y (Temp difference btw. inlet water
temp and setting water temp to stop
compressor)
0-3
℃
0
Adjustable
4
The interval for defrosting
30-90Min
40Min
Adjustable
5
Defrosting entry coil temperature
-30
℃
“-” not display
)
-7
℃
(only
display “7”)
Adjustable
6
Defrosting-off coil temp.
2-30
℃
20
℃
Adjustable
7
Defrosting max. lasting time
0-15Min
8Min
Adjustable
8
Compressor exhaust gas protection
90-120
℃
(B8)
℃
(
B8
stands
for
118
℃)
Adjustable
9
Max Pool water temp set
40~65
℃
40
Adjustable
10 Water pump running mode
0
(
Special
)
\1
(
Normal
)
0:
When target water temp
reached and unit
shutdown, water pump
keeps running.
1:
Water pump stops for
15 minutes
(adjustable by
Parameter 11)
after
compressor shutdown for
30 seconds, then water
pump starts running for 2
minutes.
NOTES: Under unit OFF
mode, if water pump
stops running for 12
hours, then water pump
will start running for 2
minutes.
1
Adjustable