background image

3-5 cm

5A

Electric radiators

CH system

5B

4

230 V

CAUTION! Do not disconnect heater 

controller when the system is powered.

The locking screw must be protected 

against accidental unscrewing eg. by 

applying a drop of lacquer or acrylic 

adhesive.

Before you apply the heating element, spread the Loctite 

glue 

(included in the set)

 on the middle of the thread 

circumference.

6A

230V

6B

230V

Live
Earth
Neutral

For the heater permanently 

connected (hard wire) there 

must be applied a cut-off 

device from the mains. 

Such a device must disconnect 

the heater from the supply 

mains in 2 poles, with contact 

separation of at least 3 mm

7

After electric connection, turn on the switch

ON/OFF 

Switch

ON/OFF 

Switch

15 cm

3

C

[ 4 ]

Summary of Contents for HOME+ H+h WiFi

Page 1: ...HEAT SYSTEM GUIDE USER MANUAL HEATER CONTROLLER H h WiFi REMOTE CONTROLER H R REMOTE CONTROLLER HEATER CONTROLLER HORIZONTAL VERTICAL E C O DES I G N R E A D Y H H_WIFI_EN0920 ...

Page 2: ...to children to preclude playing with the appliance by them Exclamation mark on triangular field signals information important for the user CAUTION electric shock hazard lightning mark ended with arrow on triangular field CAUTION in order to reduce electric shock hazard do not remove the casing nor its rear cover There are no user serviceable parts inside the appliance the product must be returned ...

Page 3: ...oller Wall clip The electric heater must have a safety valve 1 Before you apply the heating element spread the Loctite glue included in the set on the middle of the thread circumference GLUE S24 230V min 25mm C C 2 The order of assembly of elements Allen key C Option plastic overlay mask Right side Left side Heating element Heating element Heating element Vertical connection 180 Position change Mo...

Page 4: ... apply the heating element spread the Loctite glue included in the set on the middle of the thread circumference 6A 230V 6B 230V Live Earth Neutral For the heater permanently connected hard wire there must be applied a cut off device from the mains Such a device must disconnect the heater from the supply mains in 2 poles with contact separation of at least 3 mm 7 After electric connection turn on ...

Page 5: ...llation options CH system Installation options electric radiator 1 2 Mounting in radiators S24 S24 230V USER MANUAL Heating element Heater controller horizontal vertical H h 60cm 60cm Installation details 5 ...

Page 6: ... from the supply mains in 2 poles with contact separation of at least 3 mm 9B 230 V Connection with a coiled cable and a plug 4 230V CAUTION Do not disconnect heater controller when the system is powered Live Earth Neutral ON OFF Switch 9A 230V After electric connection TURN ON the switch concern only hard wire connection 10 ON OFF Switch 3 Recommendation Plug and turn front of the heater controll...

Page 7: ...er with H heater you do not need to pair it 1 For H h WiFi controller please download smartphone application from www supla org and follow the instruction USER MANUAL How to use heater controller optional remote controller VIDEO available at www homeplus system com Connect heater controller to the heater Use manufacturer recommendation Turn ON the controller ON OFF Heater controller Heater control...

Page 8: ... 5 seconds 40 C Standard heating temperature 3 sec 5 sec 2 10 C 65 C Select temperature 3 DO NOT DISCONNECT controller from heating element when connected to the power supply Lack of water or wrong choice of heating element to the heater Damaged heating element or no power cuircit No communication to the remote controller if paired Press twice upper and lower button together 2x 2x Temperature sele...

Page 9: ...DOWNLOAD APPLICATION SUPLA ORG Install the application on your devices The app will easily guide you through individual installation steps 9 ...

Page 10: ...Mników 322 32 084 Morawica Polska Tel fax 48 12 656 44 91 www heatpol pl www homeplus system com ...

Reviews: