background image

12

11

Wireless 

Series

Model

: PRT-W

Pairing the Thermostat

Pairing With the UH1-W Wiring Centre 

• 

On the receiver, press and hold the Pairing button until the Comms LED lights up.

• 

With the thermostat turned OFF, press & hold the A button for 5 seconds ...........

• 

The thermostat will send a signal for 1 minute and will flash the RF signal icon ...

• 

If pairing is successful, the Comms LED on the receiver will flash.

• 

Press the Power button on the thermostat once to confirm pairing ........................

If pairing is unsuccessful, check features 06 to 08 have been configured correctly.

To eliminate a possible signal issue, reposition the thermostat closer to the receiver and 
repeat the pairing process again.

On the UH1-W wiring centre, take note of the number set on the rotary switch

(Board ID number 1-9). 
Each UH1-W on the system needs to have a different ID number.
With the thermostat turned OFF:

• 

Press & hold the Clock button until 2 sets of numbers appear on screen ..............

• 

The small number 01 in the top right corner of the LCD is the feature number.

• 

Press Clock repeatedly until you see feature 06 (Receiver Type) .......................

The options within feature 06 are: 00 = UH1-W or 01 = RC1-W receiver.

• 

Use the Up/Down keys to set feature 06 to 00 (UH1-W) ..............................

• 

Press Clock again until you see feature 07 (UH1-W Board Address) ................

• 

Use the Up/Down keys to set the large digits to the board address

of the UH1-W. This is the number set on the UH1-W rotary switch...

(You must set a unique board address for each UH1-W installed).

• 

Press Clock again until you see feature 08 (Zone number, 01-08) ....................

• 

The UH1-W is an 8 zone receiver.

Use the Up/Down buttons to select the zone this thermostat

should be linked to ....................................................................................................

• 

Press Clock again until you see feature 09 .................................................................

(00 = Underfloor heating, 01 = Radiators.)

• 

Use the Up/Down buttons to specify whether the thermostat is

controlling underfloor heating or radiators .....................................................

• 

Press A to confirm settings and the display will go blank ....................................

• 

Press the Power button once to turn the thermostat back ON .........................

• 

Press the Up key to set the target temperature above the room

temperature; the flame symbol will appear and the assigned

zone on the UH1-W will be activated ..........................................................................

This indicates pairing between the thermostat and the UH1-W is successful.

14

13

Wireless 

Series

Model

: PRT-W

1. 

Room Temp - Indicates the current temperature sensor mode.

2. 

Day Indicator - Displays the current day.

3. 

Frost Icon - Displayed when the thermostat is in frost protection mode.

4. 

Flame Icon - Displayed when the thermostat is calling for heat, flashes when the 

Optimum Start function is in operation.

5. 

RF Icon - Flashes when the thermostat communicates with the receiver.

6. 

Temperature Hold - Displayed when manually overriding the program, “HOLD 

FOR” and the time period are displayed.

7. 

Set - Displayed when changes are made to programs or temperature set points.

8. 

Holiday Indicator - Displayed when the programmer is in holiday mode.

9. 

Current Temp - Indicates the current sensor temperature.

10.  Program Cycle Indicator - Displayed during programming only to show which 

period is being altered.

11.  Battery Level  - Indicates when the batteries require replacement.

12.  Keypad Lock Indicator - Displayed when the keypad is locked.

13.  Units of Temperature - Degrees Celsius or Fahrenheit.

14.  Clock - Digital clock display in 24h format.

LCD Display

1

2

3

4

6

7

8

9

10

12 13

14

11

5

16

15

Wireless 

Series

Model

: PRT-W

Setting the Clock

To set the clock, follow these steps.

•  With the thermostat turned ON, press the Clock key twice .................................

•  Use the Up/Down keys to set the hours ..............................................................

•  Press H to confirm settings ................................................................................................

•  Use the Up/Down keys to set the minutes .........................................................

•  Press H to confirm settings ...............................................................................................

•  Use the Up/Down keys to set the day of the week ..........................................

•  Press A to confirm settings and return to main display ..........................................

Temperature Display

Room Temperature

Set Temperature

This is the current room temperature.

This is the temperature you are trying to 

achieve in your home.

The temperature display information is driven by two different inputs; the sensor 

measurement and the target temperature you have set.

Day
Hours

Minutes

Reviews: