Pairing With the RF-Switch
•
Use the Left/Right arrow keys to scroll to SETUP and press Tick key once ................
•
The display will show 01 in the top right hand corner.
•
Press the Down arrow key once. The display will now show P1 .....................................................
•
Press Tick again to start 99 second countdown .....................................................................................
•
During the countdown press and hold either ‘Boiler’ or ‘CH1’ pairing buttons on the RF-
Switch for 5 seconds.
Boiler = When wiring to terminal marked ‘SL’ & ‘LR’
CH1 = When wiring to terminals marked ‘COM1’ & ‘NO1’
The LED on the RF-Switch will flash to indicate it’s in pairing mode. Once paired the LED will
stop flashing
.