background image

18

17

Wireless 

Series

Model:  

DT-WTS

To adjust the optional settings, follow these steps.

• 

Press PROG ......................................................................................................................

• 

Press SETUP .....................................................................................................................

• 

Use the Up/Down keys at the top of the screen to select the feature 

number (shown on page 18) and then use the Up/Down keys in the 

center to adjust the setting .......................................................................................

• 

Press DONE to confirm settings and exit ..............................................................

Adjusting the Optional Settings

Feature Number

Setting Value

01

02

03

04

05

06

FEATURE

Temperature Format

Switching Differential

Frost Protection Temperature

Output Delay

Pairing

Fail Safe

DESCRIPTION

00 = 

o

C

01 = 

o

F

(°C = Default)

0.5

o

 -  3.0

o

C  (1.0

o

C = Default)

07

o

 - 17

o

C (12

o

C = Default)

00 - 15 Minutes (00 = Default)

Used to pair with the receiver

00 = Disabled

01 = Enabled

(00 = Default)

SETTING

Optional Settings - Feature Table

Summary of Contents for DT-WTS1

Page 1: ...1 Model DT WTS Model DT WTS...

Page 2: ...mostat Installation Procedure LCD Display Pairing the Thermostat Temperature Display Clean Screen Locking the Keypad 13 14 15 16 17 18 19 20 21 22 Temperature Control Frost Protection Heating ON OFF O...

Page 3: ...heating system on and off as necessary It works by sensing the air temperature switching on the heating when the air temperature falls below the thermostat setting and switching it off once this set...

Page 4: ...thermostat from the wall plate Step B Release the desk stand Do Mount the thermostat at eye level Read the instructions fully so you get the best from our product Don t Do not push hard on the LCD sc...

Page 5: ...ery charge level 7 Room Temp Indicates the current temperature sensor mode 8 Set Indicates when changes are being made to programs or temperature set points 9 Clean Screen Freezes screen temporarily t...

Page 6: ...01 can be used in most cases but should be changed when a conflict is detected with other RF devices Use the Up Down keys to enter the address Press SETUP to Pair the thermostat and receiver Note You...

Page 7: ...eve in your home 12 11 Wireless Series Model DT WTS Keypad Lock Indicator Locking the Keypad The thermostat has a keypad lock facility To activate the lock press the bottom right corner of the display...

Page 8: ...whilst in frost mode the flame symbol will be displayed To cancel the frost protect mode press the key once Frost Mode 14 13 Wireless Series Model DT WTS Set Temperature Set Icon Frost Protection Mod...

Page 9: ...t rapid switching an output delay can be entered This can be set from 00 15 minutes The default is 00 which means there is no delay Feature 05 Pairing Function Allows the thermostat to be paired with...

Page 10: ...he setting Press DONE to confirm settings and exit Adjusting the Optional Settings Feature Number Setting Value 01 02 03 04 05 06 FEATURE Temperature Format Switching Differential Frost Protection Tem...

Page 11: ...r 10 seconds All of the screen icons will appear for 2 seconds and then disappear Press the Power key once to turn the thermostat back on Factory Reset Calibration Temperature Set Icon If you need to...

Page 12: ...battery can provide power for up to 6 months before recharging is required in normal operating conditions To recharge the battery you need to connect the thermostat to a power source A mini USB to USB...

Page 13: ...Call our support team on 44 0 1254 669090 Or view technical specifications directly on our website www heatmiser com PDF FAQ Heating Professionals Request a copy of our product installation guide cont...