7
• Use the Up/Down keys & set the large digits to the board
address of the UH1-W, this is the number set on the UH1-W
rotary switch. (You should set a unique board address on each
UH1-W installed).
• Press Clock again until you see feature 08 (Zone Number,
01-08). The UH1-W is an 8 zone receiver. Use the up/down
buttons to select the zone this thermostat should be linked to.
• Press Clock again until you see feature 09.
00 = Under-floor heating, 01 = Radiators. Use the up/down
buttons to select if the thermostat is controlling Under-Floor
heating or radiators.
• Press A to accept, the display will now go blank.
• Press the power button once to turn the thermostat back on,
press the up button & set the target temperature above the
room temperature, the flame symbol should then appear and
the assigned zone on the UH1-W should now be activated.
This indicates pairing between the thermostat & the UH1-W is
successful.