Quick Step Installation Manual
Quick Step Installation Manual
enviro
enviro
2
3
Back view in mm
453
180
153
331
43
56
109
ø58
ø65
Standard
Extended
Extended Facsia
550mm
required depth
690mm
required
height
960mm
required opening width
set the Enviro
firebo x to your
desired heigh t
ELEVATION VIEW
PLAN VIEW
Front
wall
Firebox dimensions
With it’s revolutionary design, the Enviro can be mounted at any height on the wall. You can choose to install the
Enviro at ground level with standard fascia or further up the wall with extended fascia.
Gas imput
High 42 MJ/h Low 32 MJ/h
Attaching the fascia
While attaching the facsia is straight forward, it is
important that it remains vertical all the time to make
sure the top and bottom clip in by way of clips at both
the top and bottom. (Before fascia can be removed,
door must be unscrewed and removed)
Minimum framing dimensions
Resting on the heath
If mounting the Enviro
recommended that a
non combustible hearth
be used for a minimum
Further up the wall
Extended facsia
Standard facsia
A
B
D
C
Remove all
four screws
K
eep vertical
Move fascia forward
Note: Clip in manual
control on bottom left
side of fascia
fascia clips slip
down over heat box lip
fascia clips slip
down over heat box lip
on the bottom lip also.
p
ntrol on bottom left
de of fascia
fascia clips slip
down over heat box lip
2
1
4
3
1
– Electrical power
cable (Requires
isolation switch)
2
– Incoming gas
connection (1/2” BSP
Male connector)
3
– Extraction fan
4
– Incoming air
A
B
– Your choice of pebbles, coals or logs placed into the
* C and D are only applicable if installing under bench
top and or into Joinery.
C
– Minimum enclosure height from top of box = 300mm
D
– 1 Inlet and 1 outlet ventilation with a cross sectional
area of 5000mm for each.
STEP
STEP
STEP
STEP
1
2
4
3
For inbuilt installation (into a wall)
Optional freestanding casing
• Casing H 733 x D 580 x W1080mm
• 200mm dia cut out in top of casing to allow for decorative
rigid flue (to hide flexi exhaust and air intake)
• Air holes in the back top of casing for air ventilation
• Provisional holes for both gas line and power cord in rear of
casing
When using the freestanding
casing, simply centre unit within
the casing and attach
fascia (as outlined)
1080
733
580
440
200
440
150
180
Rear View
g
g
Access panel advised for servicing if required