FILLING THE SYSTEM
First put the DHW tank under pressure before pressurizing the heating (primary)
circuit.
Filling the domestic hot water circuit
1.
Open the isolating valves (
1
) and the
draw-off tap (
2
).
2.
Once the water flow rate has stabilized
and the air is totally evacuated from
the system, close the draw-off tap (
2
).
3.
Check all the connections for leaks.
Filling of the heating circuit
1.
Open the isolating valves (
1
).
2.
Make sure that the drain valve (
3
) is
tightly closed.
3.
Open the fi lling valve (
2
).
4.
Open the air bleed valve (
4
).
5.
Once the system is bled from air,
bring the pressure to the static
pr 0.5 bar: 1.5 bar = 10m - 2
bar = 15m
Cold water
Hot water
1
1
1
2
1
1
2
3
4