GENERAL INSTALLATION INSTRUCTIONS

2.The HIP24-12B pump must be installed or maintained by a professional plumber . Install the pump according to the 

    installation diagram of the HIP24-12B pump.  Pay attention to the water pipe connection between the water inlet and the

    water outlet. After installation, check the HIP24-12B pump and all water pipe fittings for water leakage (seepage). The 

    HIP24-12B pump shall be prevented from being splashed by water to avoid electric shock.

3.After connecting the power adapter, conduct a test run of the recirculating  pump to check whether the startup is normal, 

   but the nonwater running time should not exceed 5 seconds to prevent the operation from reducing the bearing life.

4.When the HIP24-12B pump works, if you want to adjust the position of or touch the recirculating pump, the power supply 

   must be the first cut off to prevent accidents.

5.Carry out regular inspection and make replacement in time when damage occurs.

6.If the HIP24-12B pump is not used for a long time or no one is at home, please close the water pipe valve at the inlet 

   and outlet end and cut off the power supply of the recircylating pump.

7.Cable or power adapter, when damaged, must be replaced.

8.In winter, when the ambient temperature is lower than 0°C, if the electric pump stops running, the water in the pipeline 

   system must be drained to prevent the pump from freezing and cracking.

Installation steps 

HEATITCABLE.COM

4

7.2 (optional)Find a suitable installation position (on the back water pipe near the water 

 heater end). When installing the water pump support plate in advance, the support plate 

 can be placed in the pre-installation position and marked with a marker at the installation

 hole. The drilling size is φ6.

7.3 Insert the plastic expansion screw into the hole drilled in the wall. 

7.4 Fix the support plate on the wall with self-tapping screws.

7.5 Clip the pump onto the hook of the support plate indicated by the arrow.

1.For Electric Water Heater : Turn off Power to your Water Heater. (turn off power at breaker box). For Gas Water 

   Heater : Turn off the gas to your water heater and ensure that the pilot light is not burning. Shut off the supply water 

   valve to the water heater. In most cases, the supply water valve located above the hot water heater on the cold water 

   inlet to the hot water heater.

2. Shut off the supply water valve to the water heater. In most cases, the supply water valve located above the hot water 

   heater on the cold water inlet to the hot water heater.

3.Drain the water from the pipe by opening the water faucet in the house. Let the water 

   run until it stops flowing. Leave the faucet open until the pump installation is complete. 

   If water does not stop flowing, check to make sure the water to the hot water heater 

   has been completely shut off.

4.Disconnect the hot water line to the faucet with the hot water angel valve Connect the

   brass Tee to the 1/2” NPT inlet of the pump. Please make sure the rubber gasket is in 

   the brass Tee. Connect this faucet hot water line to this brass tee and then connect 

   one 1/2 inch supply line (which was provided in the package) to this brass Tee. After

   that connect this 1/2 inch supply line to the hot water angel valve. 

5.Disconnect the cold water line to faucet with the cold water angel valve. Connect the 

   brass Tee to the 1/2” NPT outlet of the pump. Please make sure the rubber gasket is 

   in the brass Tee. Connect the faucet cold water pipe to this brass tee and then connect 

   one 1/2 inch supply line (which was provided in the package) to this brass Tee. After

   that connect this 1/2 inch supply line to the cold water angel valve.

6.Use pipe dope or Teflon tape to seal threads when connecting to a 1/2 female NPT connection. If a gasket flexible 

   copper water heater connector is used pipe dope or Teflon tape is not required.

7.Ensuring that the pump shaft is horizontal. 

 

 

Summary of Contents for HIP 24-12B

Page 1: ...SMART INSTANT HOT WATER RECIRCULATING SYSTEM HEATITCABLE COM HIP 24 12B...

Page 2: ...technology Permanent magnet brush less motor DC motor makes the pump more powerful more quiet and more durable Max flow 6 GPM Max head 39 3ft Package Contents Package Contains the following Smart Hot...

Page 3: ...non corrosive non explosive liquid without solid particles fibers and mineral oil and the PH value of the medium is between 6 5 and 8 5 The requirements for the operation system of the electric pump...

Page 4: ...late on the wall with self tapping screws 7 5 Clip the pump onto the hook of the support plate indicated by the arrow 1 For Electric Water Heater Turn off Power to your Water Heater turn off power at...

Page 5: ...water temperature can t meet 10C a buzzer will sound to give an alarm Speed Mode Set 8 Reopen the supply valve to the hot water heater and allow the water to run until all the air has been purged fro...

Page 6: ...at the electric pump Power on again after cutting off the power for 10 seconds If the red light blinks remove the circulation pump and sent it back to the manufacturer for repair Check whether the ch...

Page 7: ...SISTEMA INTELIGENTE DE RECIRCULACI N DE AGUA CALIENTE INSTANT NEA HEATITCABLE COM HIP 24 12B...

Page 8: ...C con motor de im n permanente sin escobillas hace que la bomba sea m s potente m s silenciosa y m s duradera flujo m ximo 6 GPM altura m xima 39 3 pies Contenido del paquete El paquete contiene lo si...

Page 9: ...uso INSTRUCCIONES GENERALES PARA SU INSTALACI N El producto se instala debajo del grifo m s alejado del calentador de agua en cada circuito L quido transportado El l quido transportado debe ser agua...

Page 10: ...al gancho de la placa de soporte indicada por la flecha 1 Para calentadores de agua el ctricos apague la alimentaci n del calentador de agua apague la alimentaci n en la caja de interruptores Para ca...

Page 11: ...peratura del agua no puede alcanzar los 10 C sonar un timbre para dar una alarma Velocidad Modo establecido 8 Vuelva a abrir la v lvula de suministro al calentador de agua caliente y permita que el ag...

Page 12: ...nde Hay mucho aire en la bomba el ctrica Encienda nuevamente despu s de cortar la alimentaci n durante 10 segundos Si la luz roja parpadea retire la bomba de circulaci n y env ela de vuelta al fabrica...

Page 13: ...SYST ME INTELLIGENT DE RECYCLAGE INSTANTAN DE L EAU CHAUDE HEATITCABLE COM HIP 24 12B...

Page 14: ...moteur courant continu sans balai aimant permanent ce qui rend la pompe plus puissante plus silencieuse et plus durable d bit max 6 GPM hauteur de refoulement max 39 3 pieds Contenu du paquet L embal...

Page 15: ...opre non corrosif non explosif sans particules solides fibres et huile min rale et la valeur du PH du milieu est comprise entre 6 5 et 8 5 Les exigences relatives au syst me de fonctionnement de la po...

Page 16: ...mur avec des vis autotaraudeuses 7 5 Clipsez la pompe sur le crochet de la plaque de support indiqu par la fl che 1 Pour les chauffe eau lectriques coupez le courant de votre chauffe eau coupez le cou...

Page 17: ...de l eau ne peut pas atteindre 10 C un avertisseur sonore mettra un signal d alarme Vitesse Mode de fonctionnement 8 R ouvrez la vanne d alimentation du chauffe eau et laissez l eau couler jusqu ce q...

Page 18: ...pe lectrique Remise sous tension apr s avoir coup le courant pendant 10 secondes Si le voyant rouge clignote retirez la pompe de circulation et renvoyez la au fabricant pour r paration V rifier si le...

Reviews: