20. SUPPORTED COMMAND CLASSES
The following table lists all Command Classes supported by the Z-Wave
Device. The device supports both S0, S2 Authenticated security and S2
Unauthenticated security.
INSECURE
INCLUSION
INSECURE
ON SECURE
INCLUSION
SECURE
ON
SECURE
INCLUSION
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
Yes
Yes
Yes
COMMAND_CLASS_ASSOCIATION_V2
Yes
Yes
COMMAND_CLASS_MULTI_CHANNEL_
ASSOCIATION_V2
Yes
Yes
COMMAND_CLASS_ASSOCIATION_GRP_
INFO_V3
Yes
Yes
COMMAND_CLASS_TRANSPORT_
SERVICE_V2
Yes
Yes
COMMAND_CLASS_VERSION_V3
Yes
Yes
COMMAND_CLASS_MANUFACTURER_SPE-
CIFIC_V2
Yes
Yes
COMMAND_CLASS_DEVICE_RESET_
LOCALLY_V1
Yes
Yes
COMMAND_CLASS_INDICATOR_V3
Yes
Yes
COMMAND_CLASS_POWERLEVEL_V1
Yes
Yes
COMMAND_CLASS_BATTERY_V1
Yes
Yes
COMMAND_CLASS_SECURITY_V1
Yes
Yes
COMMAND_CLASS_SECURITY_2_V1
Yes
Yes
COMMAND_CLASS_NOTIFICATION_V8
Yes
Yes
COMMAND_CLASS_SUPERVISION_V1
Yes
Yes
COMMAND_CLASS_FIRMWARE_
UPDATE_MD_V5
Yes
Yes
COMMAND_CLASS_THERMOSTAT_MODE_
V3
Yes
Yes
COMMAND_CLASS_THERMOSTAT_SETPO-
INT_V3
Yes
Yes
COMMAND_CLASS_THERMOSTAT_
OPERATING_STATE_V1
Yes
Yes
COMMAND_CLASS_PROTECTION_V1
Yes
Yes
COMMAND_CLASS_CONFIGURATION_V4
Yes
Yes
COMMAND_CLASS_SENSOR_
MULTILEVEL_V5
Yes
Yes
COMMAND_CLASS_APPLICATION_
STATUS_V1
Yes
Yes
Yes
26 PRODUCT INFORMATION
PRODUCT INFO
Heatit Z-Temp2
FEATURES
•
Z-Wave thermostat for controlling external relays
•
Internal room sensor
•
Humidity sensor
•
Proximity sensor to turn on the display
•
SmartStart
•
Automatic brightness control
•
Firmware updates (OTA)
•
Weekly program/setback via gateway
•
5 associations
•
Lock mode/child lock
•
Supports encryption modes S0, S2 Authenticated Class,
S2 Unauthenticated Class
This product is a security-enabled Z-Wave Plus product with
encryption. The product must be used with a security-enabled
Z-Wave Controller in order to fully utilize the product.
TECHNICAL DATA
Protocol
Z-Wave
Chip
Z-Wave 700 chip
Rated voltage
3 x AA batteries (1,5V)
Ambient temperature
5°C to 40°C
Humidity
Max. 85% RH
Range RF
Min. 40 meters
Hysteresis
0,3°C to 3,0°C (default 0,5°C)
IP Code
IP 21
Approvals
Z-Wave Plus V2, CE,
RED 2014/53/EU, ETSI EN 301 489-1 V2.2.3 (2019-11), ETSI EN 301 489-3
V2.1.1 (2019-03), ETSI EN 300 220-1 V3.1.1 (2017-02), ETSI EN 300 220-2
V3.2.1 (2018-06), EN 62479:2010, EN 62368-1:2014+A11:2017, RoHS
2011/65/EU
MAINTENANCE
The device is maintenance-free, but must never be covered.
ART. NO.
PRODUCT
COLOR
FREQUENCY
45 126 66
Heatit Z-Temp2 thermostat Battery
White RAL 9003
EU 868,4MHz
45 126 67
Heatit Z-Temp2 thermostat Battery
Black RAL 9011
EU 868,4MHz
99 306 10
Heatit Z-Temp2 thermostat Battery
White RAL 9003
RU 869,0MHz
99 306 68
Heatit Z-Temp2 thermostat Battery
White RAL 9003
AUS 921,4MHz
Heatit Controls AB l Läkarvägen 4, 454 31 BRASTAD, SWEDEN
Phone: +47 61 18 77 77 l [email protected] –
www.heatit.com
Heatit Controls AB can not be held liable for
typographical errors, other errors or omittances in
our information. Product specifications may change
without further notice.
All electrical installations must be carried out by a
licensed electrician. The product must be installed
in accordance with national building codes and our
installers manual.
USE CASE
SENSOR TYPE
SIZE
SCALE
PRECISION
Sends tempe-
rature report
from internal
sensor
Temperatu-
re(version 1)
= 0x01
2Byte = 0x02
Celsius (°C)
= 0x00
1 decimal
= 0x01
Sends relative
humidity
report from
internal sensor
Relative humi-
dity (version 2)
= 0x05
2Byte = 0x02
Percentage
value (%)
=0x00
1 decimal
= 0x01
Notification Command Class
When the device is turned back on after a power outage (insearted
fresh batteries), the device sends a notification command to indicate
that the device is back in idle state. The Device will also send a humidity
report and temperature report when powered back on.
EVENT
TYPE
EVENT
LENGTH
Power On (OxFF)
Power maneg-
ment (0x08)
Power has been
applied (0x01)
0x00