11. CHILD LOCK - LOC

By pressing Left and Right (down and up buttons for 10 seconds,

the thermostat will display LOC. Child lock is now activated, and the lock 

icon will be lit up when the display is active. Trying to make changes from 

the display is not possible within this modus. Changes with the Z-Wave 

controller is still possible. Refer to your primary controller/gateways user 

manual on how to change the setpoint.

Child lock is deactivated by pressing Left and Right (down and up) 

buttons for 10 seconds, the thermostat will display oPn. The lock symbol 

is no longer lit when the display is active, and now you can make changes 

using buttons.

12. INVERTED OUTPUT

The thermostat can invert its signal sent to external relays. This allows 

users to use the Heatit Z-TEMP2 together with other systems. You can 

change this behaviour using a quick feature in the thermostat or, using 

Parameter 15 “Inverted Output”. 

Changing the behaviour, 

•  From physical device by holding centre and right button for 10 sec. 

•  From gateway by changing parameter 15 (for more information 

regarding the configuration parameter, see chapter “Configuration  

Parameters”).

The thermostat will display “HEA” for regular operation, and “COO” for 

inverted operation. You can check what mode you are using by holding 

centre button for 10 seconds. 

13. STANDBY AND MAIN SCREEN

When the thermostat remains untouched for a while, it will 

automatically go to standby screen. Due to power saving settings, while 

in standby, the display will be turned off. The proximity sensor will activate 

the thermostat when proximity is sensed. You can also activate the 

thermostat manually by pressing any button. 

14. Z-WAVE QR-CODE / DSK

The QR Code is needed when including using S2-Security or

SmartStart. The Z-Wave DSK can be found in the QR-Code and is

located;

1.  On the back of wall mount (above the battery compartment).

2.  Inside the packaging attached on the note.

3.  On the product packaging. 

15. SECURITY

The S2 security enhances Z-Wave Plus with an additional layer of AES 128-

bit encryption of the wireless Z-Wave communication to prevent hacking 

and man-in-middle attacks on the home network. The Heatit Z-Temp2 

supports S2 and has a Z-Wave DSK QR-Code label that may be used when 

the module is added to the Z-Wave home network. The primary controller 

will ask for a 5-digit Code, which can be found underneath the QR-Code. 

The primary controller will then ask you to confirm the rest of the code 

that is contained in the QR-Code. 

16. NODE INFORMATION FRAME

The node information frame is the business card of a Z-Wave device.

It contains information about the device type and its technical features. 

The add and remove procedure of the device is confirmed by sending 

out a node information frame. Besides this, it may be necessary for certain 

network operations to send out a node information frame.

17. ASSOCIATIONS 

Z-Wave devices interact with other Z-Wave devices. The relationship 

between one device controlling another device is called an association. 

In order to control a subordinate device, the controlling device needs to 

maintain a list of devices that will receive controlling commands. These 

lists are called ”Association Groups”. They are always related to the specific 

event triggered (e.g., sensor reports). In case the event is triggered, all 

devices stored in the respective association group will receive a joint 

wireless command.

SETTING AND REMOVING ASSOCIATIONS

Associations may be assigned and removed via Z-Wave commands.

Please refer to your primary controller/Z-Wave gateway for more 

information.

ASSOCIATION GROUPS

ROOT DEVICE

THE MAIN THERMOSTAT DEVICE

Group 1
Lifeline

Group 2
Temperature Report

Group 3
ON/OFF Control

Lifeline. (Normally used by the Z-Wave 
Controller) Sends: 
- Battery Report (sent when battery runs low).
- Notification Report (sent first time power on).
- Device Reset Locally Notification (sent if device   
  is reset).
- Indicator Report
- Thermostat Mode Report (sent when mode 
  changed from panel).
- Thermostat Setpoint Report (sent when 
  setpoint changed from panel).
- Thermostat Operating State Report (sent when  
  heating should be active).
  -  Heating - when external relay is turned ON,   
      in Standard Output 
  -  Cooling - when external relay is turned ON,  
      in Inverted Output.
- Sensor Multilevel Report (periodical reports).
- Protection Report (childlock activated/
  deactived from panel).
Max. nodes in group: 5

Multilevel Sensor Report (internal measured 
temperate and measured relative humidity). 
Max. nodes in group: 5

Binary Switch Set (normally used to control 
external relays).
Sends:
0x00 = OFF
0xFF = ON
Max. nodes in group: 5

18. CONFIGURATION PARAMETERS

Z-Wave products are supposed to work out of the box after inclusion.

Some configuration of a device can alter the functionality to better serve 

the user’s needs or unlock further enhanced features.

Parameter 1,

 Parameter Size 2. 

Temperature/ Humidity report interval

Used to adjust the time between report interval for Temperature and humidity reports.

VALUE

READ-

ONLY

ADVANCED

ALTERING 

CAPABILITIES

DESCRIPTION

30 to 32 767

0

0

0

30 to 32 767 seconds 
(Default 900)

Parameter 2, 

Parameter Size 2. 

Temperature delta value

VALUE

READ-

ONLY

ADVANCED

ALTERING 

CAPABILITIES

DESCRIPTION

0

0

0

0

Reporting tempe-
rature based on 
change is disabled

5 to 50

0.5 to 5°C 
(Default 10, 1.0°C)