Figure 26 - Flue Draft

Flue draft is measured as negative pressure in the
chimney. The amount of negative pressure determines
how strong the draft is. The draft is important because
it draws the combustion air into the fireplace and pulls
the smoke out of the chimney.

There are three basic criteria essential in establishing
and maintaining flue draft:

Availability of combustion air.

Heat generated from the fire.

Diameter and height of the flue system.

These three factors work together as a system to create
the flue draft. Increasing or decreasing any one of them
will affect the other two and thus change the amount
of draft in the entire system. See Figure 26.

If the fire is hard to start and smoke spills out of the
fireplace, or you find it difficult to establish and maintain
a moderately high burn rate, then the flue draft is too
low and corrective measures must be taken.

Be sure you have air available for combustion and that
your firewood is dry and well seasoned. Build your fires
properly and according to the instructions given in
operating instructions, “Starting a Fire”. Be sure your
flue system is installed correctly and that it is the proper
diameter and height. Check for the following:

All chimney sections are properly installed and
the joints are tightly sealed.

The chimney is clean and free of creosote
buildup.

Make sure overhanging trees and branches are
cut back within ten feet of the top of the
chimney.

Ensure the chimney cap is clean and free of
any buildup of soot or creosote.

If you still suspect you have a low draft problem it may
be necessary to increase the volume of air in your flue
system. Since the diameter of your flue system is
matched with the size of the flue collar and should not
be changed, then the height of the system must be
increased. Add chimney sections a little at a time until
the draft improves.

In some cases, regardless of what you do, it can still
be difficult to establish the proper flue draft. This is
especially evident when using an exterior factory built
chimney or exterior masonry chimney. Try placing
several sheets of crumpled paper on top of your kindling
as close to the flue outlet of the fireplace as possible.
Light this paper first then the paper under the kindling.
The heat generated from the rapidly burning paper on
top of the kindling should help get the draft established.

Still other factors can affect how well your flue system
performs. Neighboring structures, high winds, tall trees,
even hillsides can affect air currents around the
chimney. Well designed chimney caps are available
that can help. Your fireplace dealer is the local expert
in your area. He or she can usually make suggestions
or discover problems that can be easily corrected
allowing your fireplace to operate correctly as it has
been designed, providing safe and economical heat
for your home.

Summary of Contents for TRADITIONAL 4200

Page 1: ...ARNING Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to this manual For assistance or additional information consult a qualified installe...

Page 2: ...elated problems that may result from the lack of adequate combustion air It is the responsibility of the builder contractor to ensure that adequate combustion air has been provided for the fireplace 4...

Page 3: ...e of the home If you desire to put a fireplace in your basement we recommend that you consider a direct vent gas fireplace Basements always have a significant negative air pressure that causes the fir...

Page 4: ...The illustrations and diagrams used throughout these installations instructions are not drawn to scale Figure 1 Typical Fireplace System B DESCRIPTION OF THE FIREPLACE SYSTEM This fireplace system ha...

Page 5: ...i A e d i s t u O e t a r G l a r g e t n I h t i w e c a l p e r i F 2 4 3 1 M D k c a l B w e i V r a e l C d l o f i B s r o o D s s a l G B 2 4 3 1 M D s s a r B d e h s i l o P w e i V r a e l C...

Page 6: ...L S g n o l 8 4 n o i t c e S y e n m i h C 1 1 L S r e z i l i b a t S y e n m i h C 0 3 1 1 L S 0 3 n r u t e R t e s f f O y e n m i h C 8 3 5 S F t h g i a r t S p o t s e r i F 0 4 5 S F 0 3 p o...

Page 7: ...t g n e l h t g n e l e v i t c e f f E s a h t i r e t f a t r a p y e n m i h c r e h t o n a o t d e p p a n s n e e b SL11 Chimney Stabilizer SL1130 Offset Return RF570 Roof Flashing Flat to 6 12...

Page 8: ...TALLATION INSTRUCTIONS LDS33 3 x 3 LDS46 4 x 6 Decorative Shroud TR11T Round Telescoping Termination Cap ST1175 Square Termination Cap CT56 Chase Top CAK5A Chimney Air Kit TR11 Round Termination Cap T...

Page 9: ...INSTALLATION PREPARATION 1 Fireplace Locations and Space Requirements Several options are available to you when choosing a location for your fireplace This fireplace may be used as a room divider inst...

Page 10: ...the fireplace assuming combustible materials are used All required clearances to combustibles around the fireplace must be adhered to Any framing across the top of the fireplace must be above the lev...

Page 11: ...m the following steps to determine the correct chimney component combination for your particular installation b An offset and return may be attached together or a chimney section s may be used between...

Page 12: ...eplace installation d Determine the number of firestop spacers stabi lizers roof flashing etc required to complete the fireplace installation 2 Chimney Height Requirements above roof line a Major buil...

Page 13: ...w the instructions for framing on pages 9 and 10 Slide the fireplace into position Be sure to provide the minimum air clearance at the sides and back of the fireplace assembly 2 Place the Protective M...

Page 14: ...ard until the top section meets the stop bead on the lower section The inner flue is placed to the inside of the flue section below it The outer casing is placed outside the outer casing of the chimne...

Page 15: ...unsupported chimney length limitations that are given on page 11 under Chimney Requirements Check each section by pulling up slightly from the top to ensure proper engagement before installing the suc...

Page 16: ...llowing the instructions shipped with the cap For chase installations you can use a round termination cap TR11 a round telescoping termination cap TR11T or a square termination cap ST1175 A chase inst...

Page 17: ...r use in this specific model fireplace Unless the unvented gas log heater is tested and listed for use in this factory built fireplace a fire hazard may be created that can result in a structure 16 Ga...

Page 18: ...n must be installed with all fireplaces to protect the combustible floor in front of the fireplace from both radiant heat and sparks The construction of and materials used for a hearth extension are s...

Page 19: ...rials are those consisting entirely of steel iron brick tile concrete slate glass or plasters or any combination thereof c Noncombustible Sealant Material Sealants which will not ignite and burn Gener...

Page 20: ...the 8 level above the fireplace assembly This reduces heat loss through the chase 4 In cold climates the walls of the chase should be insulated to the level of the false ceiling as shown in Figure 21...

Page 21: ...op Construct a chase of desired materials maintaining a minimum 2 air space around the chimney 3 Termination Cap a Install the chimney sections up through the chase enclosure When using a TR11 round t...

Page 22: ...Appliances for Installation in Vented Fireplaces ANSI Z21 60 When operating your fireplace the flue damper must be in the open position This fireplace was not tested and listed for use with an unvent...

Page 23: ...amount of moisture in the wood The majority of the problems fireplace owners experience are caused by trying to burn wet unseasoned wood Freshly cut wood can be as much water as it is wood having a m...

Page 24: ...wood to allow air to circulate freely around and through the woodpile b Elevate the woodpile off the ground to allow air circulation underneath c The smaller the pieces the faster the drying process...

Page 25: ...imney is clean and free of creosote buildup Make sure overhanging trees and branches are cut back within ten feet of the top of the chimney Ensure the chimney cap is clean and free of any buildup of s...

Page 26: ...rred If creosote has accumulated it should be removed to reduce the risk of a chimney fire 3 Chimney Cleaning If you do detect a buildup of creosote contact a qualified chimney sweep or clean it yours...

Page 27: ...irewood 23 Flue 22 Flue Damper 22 Framing 9 10 Fuel 23 G Gas Codes 17 22 Gas Log Lighter Provisions 17 General Information 22 Glass Doors 19 Operation 23 Grate 23 H Hearth Extension 18 Positioning 19...

Page 28: ...aust fans or forced air furnaces or other causes 5 use of fuels other than those specified in the Operating Instructions 6 installation or use of components not supplied with the Fireplace or any othe...

Reviews: