6
Heatilator • NNXT33-IFT, NNXT33L-IFT, NNXT36-IFT, NNXT36L-IFT Owner’s Manual • 2628-981 Rev. D • 1/21
A. Appliance Certification
NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.
This appliance is tested and approved as either supplemen-
tal room heat or as a decorative appliance. It should not be
factored as primary heat in residential heating calculations.
NOTICE:
This installation must conform with local codes.
In the absence of local codes you must comply with the
National Fuel Gas Code, ANSI Z223.1-latest edition in
the U.S.A. and the CAN/CGA B149 Installation Codes in
Canada.
2
2
Product Specific Information
B. Glass Specifications
This appliance is equipped with 5 mm ceramic glass. Re-
place glass only with 5 mm ceramic glass. Please contact
your dealer for replacement glass.
This product is listed to ANSI standards for “Vented Gas
Fireplace Heaters” and applicable sections of “Gas Burn-
ing Heating Appliances for Manufactured Homes and
Recreational Vehicles”, and “Gas Fired Appliances for
Use at High Altitudes”.Also certified for installation in a
bedroom or bedsitting room.
C. BTU Specifications
Models
(U.S. or Canada)
Maximum
Input BTU/h
Minimum
Input
BTU/h
Orifice
Size
NNXT33-IFT
(NG)
(0-2000 FT)
29,000
16,000
#39
NNXT33L-IFT
(Propane)
(0-2000 FT)
28,000
15,750
1.55 mm
NNXT36-IFT
(NG)
(0-2000 FT)
31,000
18,500
#37
NNXT36L-IFT
(Propane)
(0-2000 FT)
29,000
15,500
#52
Installation and service of this appliance should be performed by
qualified personnel. Hearth & Home Technologies recommends
HHT Factory Trained or NFI certified professionals.
MODELS:
NNXT36-IFT, NNXT36L-IFT, NNXT33-IFT,
NNXT33L-IFT
LABORATORY:
Underwriters Laboratories, Inc. (UL)
TYPE:
Direct Vent Heater
STANDARD:
CSA / ANSI Z21.88:19 • CSA 2.33:19