Heatilator NNXT33-IFT Owner'S Manual Download Page 5

5

Heatilator  •  NNXT33-IFT, NNXT33L-IFT, NNXT36-IFT, NNXT36L-IFT Owner’s Manual  •  2628-981 Rev. D  •  1/21 

WARRANTY CONDITIONS:

•  Because HHT cannot control the quality of any Products sold by unauthorized sellers, this Warranty only covers Products that are 

purchased through an HHT authorized dealer or distributor unless otherwise prohibited by law; a list of HHT authorized dealers 

is available on the HHT branded websites. 

•  This Warranty is only valid while the applicable Product remains at the site of original installation. 
•  This Warranty is only valid in the country in which the HHT authorized dealer or distributor that sold the applicable Product is 

authorized to sell applicable Product. 

•  Contact your installing distributor or dealer for Warranty service. If the installing dealer or distributor is unable to provide 

necessary parts, contact the nearest HHT authorized dealer or supplier. Additional service fees may apply if you are seeking 

Warranty service from a dealer other than the dealer from whom you originally purchased the applicable Product.

•  No HHT consumer should bear cost of warranty service or costs incurred while servicing warranty claims (i.e., travel, gas, or 

mileage) when the service is performed within the terms of this Warranty. Check with your dealer or distributor in advance for 

any costs to you when arranging a warranty call. Travel and shipping charges for parts are not covered by this Warranty. 

WARRANTY EXCLUSIONS:

This Warranty does not cover the following:

•  Changes in surface finishes as a result of normal use. As a heating appliance, some changes in color of interior and exterior surface 

finishes may occur. This is not a flaw and is not covered under the Warranty. 

•  Damage  to  printed,  plated,  or  enameled  surfaces  caused  by  fingerprints,  accidents,  misuse,  scratches,  melted  items  or  other 

external sources and residues left on the plated surfaces from the use of abrasive cleaners or polishes. 

•  Repair or replacement of parts that are subject to normal wear and tear during the Warranty Period are not covered. These parts 

include: paint, wood and pellet gaskets, firebricks, grates, flame guides, batteries and the discoloration of glass. 

•  Minor expansion, contraction, or movement of certain parts causing noise. These conditions are normal and complaints related to 

this noise are not covered by this Warranty.

•  Damages  resulting  from:  (1)  failure  to  install,  operate,  or  maintain  the  applicable  Product  in  accordance  with  the  installation 

instructions,  operating  instructions,  and  listing  agent  identification  label  furnished  with  the  applicable  Product;  (2)  failure  to 

install the applicable Product in accordance with local building codes; (3) shipping or improper handling; (4) improper operation, 

abuse, misuse, continued operation with damaged, corroded or failed components, accident, or improperly/incorrectly performed 

repairs; (5) environmental conditions, inadequate ventilation, negative pressure, or drafting caused by tightly sealed constructions, 

insufficient make-up air supply, or handling devices such as exhaust fans or forced air furnaces or other such causes; (6) use of fuels 

other than those specified in the operation instructions; (7) installation or use of components not supplied with the applicable 

Product or any other components not expressly authorized and approved by HHT; (8) modification of the appliance not expressly 

authorized and approved by HHT in writing; and/or (9) interruptions or fluctuations of electrical power supply to the applicable 

Product. 

•  Non-HHT venting components, hearth connections or other accessories used in conjunction with the applicable Product. 

•  Any part of a pre-existing fireplace system in which an insert or a decorative gas applicable Product is installed. 

•  HHT’s obligation under this Warranty does not extend to the Product’s capability to heat the desired space. Information is provided 

to assist the consumer and the dealer in selecting the proper Product for the application. Consideration must be given to the 

Product location and configuration, environmental conditions, insulation and air tightness of the structure. 

This warranty is void if:

•  The  applicable  Product  has  been  over-fired,  operated  in  atmospheres  contaminated  by  chlorine,  fluorine,  or  other  damaging 

chemicals. Over-firing can be identified by, but not limited to, warped plates or tubes, deformation/warping of interior cast iron 

structure or components, rust colored cast iron, bubbling, cracking and discoloration of steel or enamel finishes. 

•  The applicable Product is subjected to prolonged periods of dampness or condensation. 

•  There is any damage to the applicable Product due to water or weather damage which is the result of, but not limited to, improper 

chimney or venting installation. 

LIMITATIONS OF REMEDIES AND LIABILITY:

•  EXCEPT TO THE EXTENT PROVIDED BY LAW, HHT MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY SPECIFIED 

HEREIN. The owner’s exclusive remedy and HHT’s sole obligation under this Warranty or in contract, tort or otherwise, shall be 

limited to replacement of the Component Part(s), repair of the Component Part(s), or refund of the original purchase price of the 

applicable Product(s), as specified above; provided, however, that (i) if HHT is unable to provide replacement of the Component 

Part(s) and repair of the Component Part(s) is not commercially practicable or cannot be timely made, or (ii) the customer is 

willing to accept a refund of the purchase price of the applicable Product(s), HHT may discharge all such obligations by refunding 

the purchase price of the applicable Product. In no event will HHT be liable for any incidental or consequential damages caused 

by defects in the applicable Product. Some States do not allow the exclusion or limitation of incidental or consequential damages, 

so the above limitation or exclusion may not apply to you. This Warranty gives you specific legal rights and you may also have 

other rights which vary from State to State. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF THE 

EXPRESSED WARRANTY SPECIFIED ABOVE FOR THE APPLICABLE PRODUCT. Some States do not allow limitations on how long an 

implied warranty lasts, so the above limitation may not apply to you. 

Page 2 of 2

4021-645L  10/20

Summary of Contents for NNXT33-IFT

Page 1: ...neighbor s phone Follow the gas sup plier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury death or property damage Models NNXT33 IFT NNXT33L IFT NNXT36 IFT NNXT3...

Page 2: ...Pression xx x in w c Po Col D eau Maximum Manifold Pressure Pression x x in w c Po Col d eau Minimum Manifold Pressure Pression x x in w c Po Col d eau Minimum rate with variable regulator on control valve Total Electrical Requirements 120Vac 60Hz less than 12 Amperes MADE IN USA USA CANADA ALTITUDE 0 2000 FT 0 4500 FT MAX INPUT BTU h xx xxxx xx xxx MIN INPUT BTU h xx xxx xx xxx ORIFICE SIZE xx DM...

Page 3: ...fetime Warranty 4 2 Product Specific Information A Appliance Certification 6 B Glass Specifications 6 C BTU Specifications 6 3 Important Safety and Operating Information A Appliance Safety 7 B General Operating Parts 8 C Fuel Specifications 8 D Wall and Mantel Temperatures 8 E Wall Surface TV Guidelines 8 F Before Lighting Appliance 10 G Lighting Instructions IPI 11 H Appliance Break In 12 I Heat ...

Page 4: ...pendent authorized HHT dealer or distributor whichever occurs earlier However the Warranty coverage shall commence no later than 24 months following the date of Product shipment from HHT regardless of the installation or occupancy date The term Lifetime in the table below is defined as 20 years from the beginning date of warranty coverage for gas appliances and 10 years from the beginning date of ...

Page 5: ...andling devices such as exhaust fans or forced air furnaces or other such causes 6 use of fuels other than those specified in the operation instructions 7 installation or use of components not supplied with the applicable Product or any other components not expressly authorized and approved by HHT 8 modification of the appliance not expressly authorized and approved by HHT in writing and or 9 inte...

Page 6: ...our dealer for replacement glass This product is listed to ANSI standards for Vented Gas Fireplace Heaters and applicable sections of Gas Burn ing Heating Appliances for Manufactured Homes and Recreational Vehicles and Gas Fired Appliances for Use at High Altitudes Also certified for installation in a bedroom or bedsitting room C BTU Specifications Models U S or Canada Maximum Input BTU h Minimum ...

Page 7: ...s High temperatures may ignite clothing or other flammable materials Clothing furniture draperies and other flammable materials must not be placed on or near the appliance WARNING This product and the fuels used to operate this product liquid propane or natural gas and the products of combustion of such fuels can expose you to chemicals including benzene which is known to the State of California t...

Page 8: ...NOT REQUIRED CLEAR SPACE SECTION 3 A FAN SECTION 6 A CONTROL CAVITY SECTION 3 I NOTICE Surface temperatures listed above are taken with a temperature measuring probe as prescribed by the test standard used for appliance certification Temperatures on walls or mantels taken with an infrared thermometer may yield increased temperatures of up to 30 F 17 C or more depending on the thermometer settings ...

Page 9: ...and from model to model actual TV temperatures should be validated at the time of each installation TVs should not be used in situations where the actual TV temperature exceeds the manufacturers maximum allowable operating temperatures identified in the TV s technical specifications Contact the TV s manufacturer directly if you cannot locate this information or have questions regarding the informati...

Page 10: ...shipping materials have been removed from inside and or underneath the firebox Review proper placement of logs ember material and or other decorative materials Check the wiring Check the air shutter adjustment Ensure that there are no gas leaks Ensure that the glass is sealed and in the proper position and that the integral barrier is in place WARNING Risk of Fire or Asphyxiation DO NOT op erate f...

Page 11: ...plier s instructions If you cannot reach your gas supplier call the fire department C Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand DO NOT try to repair it call a qualified service technician Force or attempted repair may result in a fire or explosion D DO NOT use this appliance if any part has been under water Immediately c...

Page 12: ... smoke and odors Smoke detectors may activate Optional Heat Zone Gas Kit The Heat Zone Gas heat management option is avail able for use with the NNXT IFT appliances and must be used in conjunction with the IFT RC400 remote control The Heat Zone Kit draws heat from your fireplace to an adjacent room in your home up to 20 feet away Optional Heat Out Gas Kit The Heat Out Gas heat management option is...

Page 13: ...rier front and front refractory may need to be removed 2 Locate the battery tray and insert four AA cell batteries Battery polarity must be correct or module damage will occur See Figure 3 5 A complete wiring diagram is included in the Electrical section of the appliance Installation Manual 3 Turn the appliance on according to the instructions below for the appropriate type of control Wall Switch ...

Page 14: ...o the OFF position while the appliance is operating the system will shut down ON Position The appliance will ignite and run continuously at the HI flame setting No adjustment in flame height is possible Remote Position The remote position allows operation of the appliance from a wired wall switch IFT RC400 or IFT RC150 remote controls The IFT ECM switch must be in this position to pair the IFT ECM...

Page 15: ... corrected If the IFT ECM re enters the lock out condition after these steps call your dealer for service Fan ON OFF The fan may be turned on and off and the speed adjusted by the remote control that comes standard with the fire place Consult the instructions included with the appli ance remote control for more information Appliance ON OFF Use the factory installed IntelliFire Touch RC400 Remote C...

Page 16: ...hall be turned off and cooled before servicing When properly maintained your fireplace will give you many years of trouble free service Contact your dealer to answer questions regarding proper operation trouble shooting and service for your appliance Visit www heati lator com to locate a dealer We recommend annual ser vice by a qualified service technician IMPORTANT Any safety screen decorative ba...

Page 17: ...vent unin tended operation Remove batteries from remote controls Unplug the 6 volt adapter plug Clean glass with a non abrasive non ammonia based commercially available gas fireplace glass cleaner Light deposits Use a soft cloth with soap and water Heavy deposits Use commercial fireplace glass cleaner consult with your dealer Carefully set fixed glass assembly in place on fireplace Hold glass in p...

Page 18: ...avoided Remove all foreign objects Verify unobstructed air circulation Figure 4 2 IPI Pilot Flame Pattern Pilot and Burner Ignition and Operation Frequency Annually By Qualified Service Technician Tools needed Protective gloves vacuum cleaner whisk broom flashlight voltmeter indexed drill bit set and a manometer Inspect orifice for soot dirt and corrosion Verify orifice size is correct See Service...

Page 19: ... hours This is caused by the curing of the paint and the burning off of any oils remaining from manufacturing Odor may also be released from finishing materials and adhesives used around the fireplace These circumstances may require additional curing related to the installation environment Film on the glass This is a normal result of the curing process of the paint and logs Glass should be cleaned...

Page 20: ...fference between the desired room temperature and actual temperature In thermostat mode the hearth appliance will start in HI flame but as the actual temperature approaches the desired set temperature on the remote the flame intensity will automatically decrease Au tomatic flame modulation will result in more control of the tem perature and will cause the appliance to cycle OFF ON less The applian...

Page 21: ... IFT ECM slider switch is in ON or REM position Verify AC power available to junction box Verify AC DC adaptor is plugged into junction box and ECM Verify AC DC adaptor out put voltage is between 5 7 6 3 Vdc If battery pack is used check battery pack voltage is 4 2 V if not replace batteries Shorted or loose connection in system wiring or wiring harness Verify system wiring configuration Remove an...

Page 22: ...ted to green main valve solenoid Check main valve solenoid resistance nominal is 60 ohms If open or shorted replace valve Verify valve inlet pressure is correct for gas type Pilot and main do not light ECM goes into 5 Red 1 Green Lockout Power Vent PV Failure Power Vent blower defective check wiring to IFT ACM check if blower is working Check if PV pressure switch is connected to brown and black w...

Page 23: ...ies if the barrier is not present or help is needed to properly install one For more information refer to the instructions supplied with your decorative barrier door or front Heat Management Systems The optional heat management systems compatible with this product are discussed in Section 3 I After a qualified service technician has installed the heat management system follow the instruction suppl...

Page 24: ...al 2628 981 Rev D 1 21 Service Parts Beginning Manufacturing Date Sept 2020 Ending Manufacturing Date Active Part number list on following page Log Set Assembly 08 20 NNXT33 IFT NNXT36 IFT 8 9 10 11 12 13 14 15 17 19 18 20 21 22 25 7 16 26 23 24 4 5 1 2 3 6 B Service Parts ...

Page 25: ...0 Non Combustible Board 4055 894 11 Glass Baffle 2384 109 12 Hearth Pan 2384 111 13 Burner Assembly NG Propane 2384 007 Y 14 Valve Assembly NG Refer to valve page 15 Gasket Valve Plate Qty 2 req 4055 135 16 Glass Frame Assembly GLA2384 018 Y 17 Ignition Control Assembly Refer to valve page 18 Glass Retainer Qty 2 req 060 235 25 19 Glass Latch Assembly Qty 4 req 2382 400 Y 20 Junction Box SRV2326 0...

Page 26: ...0 Non Combustible Board 4055 895 11 Glass Baffle 2385 109 12 Hearth Pan 2385 111 13 Burner Assembly NG Propane 2385 007 Y 14 Valve Assembly NG Refer to valve page 15 Gasket Valve Plate Qty 2 req 4055 135 16 Glass Frame Assembly GLA2385 018 Y 17 Ignition Control Assembly Refer to valve page 18 Glass Retainer Qty 2 req 060 235 25 19 Glass Latch Assembly Qty 4 req 2382 400 Y 20 Junction Box SRV2326 0...

Page 27: ...former SRV2326 131 Y 14 10 Wire Harness IFT 6 Pin SRV2326 132 Y 14 11 Air Shutter Assembly SRV4055 202 Y 14 12 Gasket Bulkhead 4021 429 14 13 Bulkhead W Flex Tube 4021 512 Y 17 1 Heat Sheild Component 2628 110 17 2 Cable B Type AC Module SRV2326 152 Y 17 3 Module IFT Control SRV2326 130 Y 17 4 Module RF FCC SRV2326 120 Y 17 5 Module B Type AC SRV2326 150 Y 17 6 Battery Pack SRV2326 134 Y 17 7 Tray...

Page 28: ...___________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ...

Reviews: