MHST36D INSTALLATION INSTRUCTIONS
CLEARANCES!
A minimum 1/2 in. air
clearance must be
maintained at the sides
of the fireplace as-
sembly.
Chimney sections at
any level require a 2 in.
minimum air space
clearance between
the framing and chim-
ney section.
WARNING!
1. Do not install in sleeping rooms.
2. Combustion air needs of a heavily fired fireplace may deplete the available oxygen supply.
Figure 2 - Fireplace Locations
D. PRE-INSTALLATION PREPARATION
1. Fireplace Locations and Space Requirements
Several options are available to you when choosing a location for your fireplace. This fireplace may be used as a
room divider or installed along a wall. See Figure 2.
Locating the fireplace in a basement, near frequently opened doors, central heat outlets or returns, or other locations
of considerable air movement can affect the performance and cause intermittent smoke spillage from the front of the
fireplace. Consideration should be given to these factors before deciding on a location.