background image

12

31068 Rev E

08/04

MHST36D INSTALLATION INSTRUCTIONS

WARNING!

Do not combine offsets to create an offset greater than 30 deg from verti-
cal. This may create a fire hazard since the natural draft may be restricted.

1. Using Offsets and Returns

a.

To bypass any overhead obstructions, the chimney may be offset using a 15-deg (SL315) or 30- deg (SL330)
offset/return.  Perform the following steps to determine the correct chimney component combination for your
particular installation.

b.

An offset and return may be attached together or a chimney section(s) may be used between an offset and
return.

1)

Measure how far the chimney needs to be shifted to enable it to avoid the overhead obstacle. See Figure 5,
dimension “A” to determine chimney sections required to achieve the needed shift.

2)

After determining the offset dimension, refer to Table 1 and find the “A” dimension closest to 

but not less

than 

the distance of shift needed for your installation.

3)

The “B” dimension that coincides with the “A” dimension represents the required vertical clearance that is
needed to complete the offset and return.

4)

Read across the chart and find the number of chimney sections required and the model number of those
particular chimney parts.

5)

Whenever the chimney penetrates a floor/ceiling, a firestop spacer must be installed.

6)

The effective height of the fireplace assembly is measured from the base of fireplace to top of starter col-
lar (47-1/4 in.).

Example: 

Your “A”

dimension from Figure 5 is
14-1/2 in. Using Table 1 the
dimension closest to, but
not less than 14-1/2 in. is
14-5/8 in. using a 30-deg
offset/return. It is then
determined from the table
that you would need 33 in.
(Dimension “B”) between
the offset and return. The
chimney components that
best fit your application are
two SL312s.

Figure 5 - Chimney Offset/

Return

* Proper assembly of air cooled chimney parts result in an overlap at chimney joints

of 1-1/4 in. Effective length is built into this chart.

Table 1

Offset Chart*

A

B

A

B

1-5/8  in. 13-3/8  in. 3-7/8  in. 14-1/2  in.

-

-

-

-

-

-

2-7/8  in. 17-3/4  in. 6-1/4  in. 18-5/8  in.

1

-

-

-

-

-

4-1/8  in. 22-3/8  in. 8-5/8  in. 22-3/4  in.

2

-

-

-

-

-

4-1/2 in. 23-5/8 in. 9-1/4 in. 23-3/4 in.

-

1

-

-

-

-

5-3/4 in. 28-1/4 in. 11-5/8 in. 27-7/8 in.

1

1

-

-

-

-

6 in.

29-3/8 in. 12-1/4 in. 29 in.

-

-

1

-

-

-

7-1/4 in.

34 in. 14-5/8 in. 33 in.

-

2

-

-

-

-

7-3/4 in. 36-1/8 in. 15-1/4 in. 34-1/8 in.

-

-

-

1

-

-

8-3/4 in. 39-3/4 in. 17-5/8 in. 38-1/4 in.

1

-

-

1

-

-

10-3/8 in. 45-5/8 in. 20-5/8 in. 43-1/2 in.

-

-

2

-

-

-

10-5/8  in. 46-3/4  in. 21-1/4  in. 44-5/8  in.

-

-

-

-

1

-

11-7/8 in. 51-3/8 in. 23-5/8 in. 48-3/8 in.

1

-

-

-

1

-

13-1/2 in. 57-1/4 in. 26-5/8 in. 53-7/8 in.

-

-

-

2

-

-

13-3/4  in. 58-3/8  in. 27-1/4  in. 55-3/4  in.

-

-

-

-

-

1

15  in.

63  in. 29-5/8  in. 59  in.

1

-

-

-

-

1

16-1/2 in. 68-3/4 in. 32-5/8 in. 64-1/4 in.

-

1

-

-

-

1

18 in. 74-5/8 in. 35-5/8 in. 69-1/2 in.

-

-

1

-

-

1

19-5/8 in. 80-3/8 in. 38-5/8 in. 74-5/8 in.

-

-

-

1

-

1

20-5/8 in. 84-1/8 in. 41 in. 78-3/4 in.

1

-

-

1

-

1

22-3/4  in. 91-7/8  in. 44-5/8  in. 85  in.

-

-

-

-

1

1

24 in. 96-1/2 in. 47 in. 89-1/8 in.

1

-

-

-

1

1

25-7/8 in.103-1/2 in.50-5/8 in. 95-1/2 in.

-

-

-

-

-

SL318

SL324

SL336

SL348

15-degree

30-degree

SL306

SL312

Summary of Contents for MHST36D

Page 1: ...injury or property damage Refer to this manual For assistance or additional information consult a qualified installer service agency or the gas supplier INSTALLATION OPERATING INSTRUCTIONS MHST36D WO...

Page 2: ...problems that may result from the lack of adequate combustion air It is the responsibility of the builder contractor to ensure that adequate combustion air has been provided for the fireplace 4 The f...

Page 3: ...the home If you desire to put a fireplace in your basement we recommend that you consider a direct vent gas fireplace Basements always have a significant negative air pressure that causes the firepla...

Page 4: ...arances must be maintained at all times The illustrations and diagrams used throughout these installation instructions are not drawn to scale Figure 1 A Typical Fireplace System B DESCRIPTION OF THE F...

Page 5: ...ral Grate Outside Air Kit and Hearth Protection Strips DM1036 Bi fold Glass Doors Black Finish DM1036B Bi fold Glass Doors Polished Brass Finish included with fireplace DM1036S Bi fold Glass Doors Sta...

Page 6: ...g SL324 Chimney Section 24 in long SL336 Chimney Section 36 in long SL348 Chimney Section 48 in long SL315 Chimney Offset Return 15 deg SL330 Chimney Offset Return 30 deg JB877 Chimney Joint Band CB87...

Page 7: ...ashing 6 12 to 12 12 Pitch RF371 Roof Flashing Flat to 6 12 Pitch CAK4A Chimney Air Kit Firestop Spacer Catalog A B FS338 0 deg 14 1 2 in FS339 15 deg 18 3 8 in FS340 30 deg 23 in Catalog A B SL306 6...

Page 8: ...supply Figure 2 Fireplace Locations D PRE INSTALLATION PREPARATION 1 Fireplace Locations and Space Requirements Several options are available to you when choosing a location for your fireplace This fi...

Page 9: ...e precautions will reduce the possibility of fireplace smoking or air flow reversal WARNING To prevent contact with sagging or loose insulation the fireplace must not be installed against vapor barrie...

Page 10: ...ST36D fireplace will fit a framed opening of 41 in wide x 42 in tall The finished cavity depth must be no less than 23 in Figure 3 shows a typical framing using 2 x 4 lumber of the fireplace assuming...

Page 11: ...ded area E CHIMNEY REQUIREMENTS When planning your fireplace location the chimney construction and necessary clearances must be considered The fireplace system and chimney components have been tested...

Page 12: ...measured from the base of fireplace to top of starter col lar 47 1 4 in Example Your A dimension from Figure 5 is 14 1 2 in Using Table 1 the dimension closest to but not less than 14 1 2 in is 14 5...

Page 13: ...ntal distance from the side of the chimney to the peak of the roof is 10 ft or less the top of the chimney must be at least 2 ft above the peak of the roof but never less than 3 ft in overall height a...

Page 14: ...instructions for framing on pages 8 11 Slide the fireplace into position Be sure to provide the minimum air clearance at the sides and back of the fireplace assembly 2 Place the Protective Metal Hear...

Page 15: ...op bead on the lower section The inner flue is placed to the inside of the flue section below it The outer casing is placed outside the outer casing of the chimney section below it See Figure 8 5 Inst...

Page 16: ...ney system a Bend the tabs at the top of the attic insulation shield inward This will help keep the chimney section centered in the shield b Position the shield over the vertical chimney section where...

Page 17: ...n The extension should overlap the thimble one inch c To attach the extension to the thimble drill 1 8 in holes through the outer shield of the thimble using the predrilled holes in the extension as g...

Page 18: ...wn 10 Install the Outside Air Kit The outside air kit is supplied as a standard feature with this fireplace and its use is required to minimize the effects of negative pressure within the structure It...

Page 19: ...n this specific model fireplace Unless the unvented gas log heater is tested and listed for use in this factory built fireplace a fire hazard may be created that can result in a structure fire 13 Gas...

Page 20: ...n must be installed with all fireplaces to protect the combustible floor in front of the fireplace from both radiant heat and sparks The construction of and materials used for a hearth extension are s...

Page 21: ...of steel iron brick tile concrete slate glass or plasters or any combination thereof c Noncombustible Sealant Material Sealants which will not ignite and burn General Electric RTV103 Black or equivale...

Page 22: ...or Installation in Vented Fireplaces ANSI Z21 60 When operating your fireplace the flue damper must be in the open position This fireplace was not tested and listed for use with an unvented gas log he...

Page 23: ...a greater density than soft woods A piece of hardwood will contain about 60 more BTU s than an equal size piece of soft wood Firewood is commonly sold by the cord 128 cu ft A cord of seasoned oak hard...

Page 24: ...wood to allow air to circulate freely around and through the woodpile b Elevate the woodpile off the ground to allow air circulation underneath c The smaller the pieces the faster the drying process...

Page 25: ...y is clean and free of creosote buildup Make sure overhanging trees and branches are cut back within ten feet of the top of the chimney Ensure the chimney cap is clean and free of any buildup of soot...

Page 26: ...ed If creosote has accumulated it should be removed to reduce the risk of a chimney fire 3 Chimney Cleaning If you do detect a buildup of creosote contact a qualified chimney sweep or clean it yoursel...

Page 27: ...s Knockout Location 6 Gas Log Lighter Provisions 19 General Information 22 Glass Doors 5 21 23 Grate 5 23 H Hearth Extension 20 Positioning 21 I Installation Fireplace 14 Insulation Shield 16 J Joint...

Page 28: ...haust fans or forced air furnaces or other causes 5 use of fuels other than those specified in the Operating Instructions 6 installation or use of components not supplied with the Fireplace or any oth...

Reviews: