Heatilator • LM42 • Installers Manual • 4087-901 • Rev A • 04/14/16
4
C. Non-Combustible Materials
• Materials which will not ignite and burn, composed of
any combination of the following:
- Steel
- Iron
- Brick
- Tile
- Concrete
- Slate
- Glass
- Plasters
• Materials reported as passing
ASTM E 136, Standard
Test Method for Behavior of Metals, in a Vertical
Tube Furnace at 750° C
D. Combustible Materials
• Materials made of or surfaced with any of the following
materials:
- Wood
- Compressed paper
- Plant fibers
- Plastic
- Plywood/OSB
- Sheet rock (drywall)
- Foam insulation & sealants
• Any material that can ignite and burn; flame proofed or
not, plastered or un-plastered
1
Product Specific & Important Safety Information
Section 1
B. Glass Specifications
• This appliance is equipped with 5mm ceramic glass.
Please contact your dealer for replacement glass.
Not intended for use as a primary heat source.
This
fireplace is tested and approved as a decorative
fireplace. It should not be factored as a primary heat
source in residential heating calculations.
Improper installation, adjustment, alteration, service
or maintenance can cause injury or property damage.
Refer to the owner’s information manual provided with
this fireplace. For assistance or additional information
consult a qualified installer, service agency or your
dealer.
WARNING
Fire Risk
WARNING
TO AVOID THE RISK OF DAMAGING FIREPLACE MA
-
TERIALS AND INCREASING THE RISK OF SPREAD
-
ING A FIRE,
DO NOT USE THE FIREPLACE TO
COOK OR WARM FOOD.
WARNING!
THIS FIREPLACE MAY BE INSTALLED IN
MANUFACTURED HOMES, EXCEPT IN SLEEPING
ROOMS.
If installed with a gas log set, provisions for the National
Fuel Gas Code must be met.
This fireplace complies with the installation requirements
for HUD.
CAUTION!
THE STRUCTURAL INTEGRITY OF THE
MANUFACTURED HOME FLOOR, WALL, AND CELING/
ROOF MUST BE MAINTAINED.
Heatilator is a registered trademark of Hearth & Home
Technologies.
WARNING! Risk of Fire!
Hearth & Home Technologies
disclaims any responsibility for, and the warranty and
agency listing will be voided by the following actions.
DO NOT:
• install or operate damaged fireplace
• modify fireplace
• install other than as instructed by Hearth & Home
Technologies
• operate the fireplace without fully assembling all
components
• overfire
• install unvented gas log set
• install any component not approved by Hearth & Home
Technologies
• install parts or components not Listed or approved
Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage. For
assistance or additional information, consult a qualified
installer, service agency or your dealer.
A. Fireplace Certification
This fireplace system has been tested and listed in accor
-
dance with UL 127 and ULC-S610 standards by Underwrit
-
ers Laboratories Inc. for installation and operation in the
United States and Canada.