01-03
11
34613 Rev F
NOVUS SERIES INSTALLATION INSTRUCTIONS
c. Vent Lengths for Rear Vent
1) No Elbows
The maximum horizontal run, with no vertical
sections of vent, is 18 from the back of the
appliance to the base of the cap. See
Figure 14.
2) A 45° Elbow
For corner installations with horizontal
venting, a maximum of one 45° elbow may
be used. The maximum horizontal run
following the elbow is 18 to the base of the
cap and will include the 45° elbow, and a
termination cap. See Figure 15.
Figure 14
No Elbows
3) Two Elbows
Elbows used on rear vented configurations
should be either a 90° elbow or a 45° elbow.
A starter elbow cannot be used in any rear
vent configuration.
Figure 16 shows various
venting configurations using two elbows to
terminate horizontally.
Figure 15
One 45° Elbow
4) Three Elbows
Elbows used on rear vented configurations
should be either a 90° elbow or a 45° elbow.
A starter elbow cannot be used in any rear
vent configuration.
Figure 17 shows various venting
configurations using three elbows to terminate
horizontally.
Figure 16
Two Elbows
Figure 17
Three Elbows