Heatilator • GDST3831I • 2127-900 Rev. N • 6/15
42
TRANSFORMER
3 VAC
PLUG IN
BLACK
RED
BATTERY PACK
WIRE ASSEMBLY
WIRES
(TO BROWN)
ORANGE
GREEN
VALVE
HOT
NEUTRAL
GROUND TO
FIREPLACE
CHASSIS
WHITE
ORANGE
IGNITION
MODULE 3 VAC
INTERMITTENT
PILOT IGNITOR
I
S
Figure 12.1 Intelli
fi
re Ignition Wiring Diagram with Wall Switch or Thermostat
TRANSFORMER
3 VAC
PLUG IN
PLUG IN
BLACK
RED
BATTERY PACK
REMOTE
WIRES
(TO BROWN)
ORANGE
GREEN
VALVE
GROUND TO
FIREPLACE
CHASSIS
HOT
NEUTRAL
WHITE
ORANGE
IGNITION
MODULE 3 VAC
INTERMITTENT
PILOT IGNITOR
I
S
Figure 12.2 Intelli
fi
re Ignition Wiring Diagram with Remote Receiver
NOTE: 1
. Ignition module, valve, pilot, and
wall switch operate on 3 volts. 110-120 VAC
is required at junction box unless equipped
with battery back-up.