18

Service Parts

Beginning Manufacturing Date: N/A 

Ending Manufacturing Date: Active

FI42M, FI42ML

IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement 

parts for your appliance please provide model number and serial number. All parts listed 

in this manual may be ordered from an authorized dealer.

Stocked 

at Depot

ITEM

DESCRIPTION

COMMENTS

PART NUMBER

1

Back Log

SRV32233

2

Front Log

SRV32234

3

Top Right Log

SRV33732

4

Top Left Log

SRV33733

5

Grate Assembly

33743

6

Burner Assembly

33725

Y

7

Control Module

593-592

Y

8

Brass Connector

Pkg of 5

303-315/5

Y

9

Valve NG

593-500

Y

Valve LP

593-501

Y

10

Brass Male Connector

13425

11

Gas Tube

33729

12

Ori

 ce NG (.182)

32230

Ori

 ce LP (.110)

17235

Y

13

Bulkhead

13405A

14

Pilot Assembly NG

4021-730

Y

Pilot Assembly LP

4021-731

Y

15

Pilot Bracket

33375

16

Battery Pack

593-594A

Y

17

ON/OFF Rocker Switch

060-511

Y

18

Access Cover

32238

Damper Stop Assembly

14354

Y

10 in. Flexline

302-320A

Y

Dexen Wire Harness

593-590A

Y

Wool, Rock, Vermiculite

34010

Lava Rock (2lb. Bag)

4021-296

Mineral Wool

14333B

Vermiculite

28746

"Z" Bracket

32228

Wire Harness

Qty 2 req

33995

Conversion Kit NG

DCKN

Y

Conversion Kit LP

DCKP

Y

Pilot Ori

 ce NG, .021

446-505

Y

Pilot Ori

 ce LP, .011

446-517

Y

Regulator NG 

NGK-DXF

Y

Regulator LP

LPK-DXF

Y

Installation Manual

33734

Summary of Contents for Fi36M

Page 1: ...causing property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance What to do if you smell gas D...

Page 2: ...This will prevent possible electrical shock or burns Also make sure the fireplace is completely cooled before servicing 7 Solid fuels cannot be burned in a fireplace where the decorative gas appliance...

Page 3: ...erated as a system Any alteration to or substitution for items in this system unless allowed by these installation instruc tions will void the Underwriters Laboratories listing and may void the produc...

Page 4: ...to natural gas The conversion kits for all S series log sets are CKMP to convert from natural to propane gas CKMN to convert from propane to natural gas These HEATILATOR gas log sets and components h...

Page 5: ...t pressure equal to or less than 1 2 PSIG The minimum size fireplace in which the log set can be installed and the minimum permanent free opening that must be provided by either the fireplace chimney...

Page 6: ...l the Damper Stop To install the damper stop Open the damper to the fully open position and secure it open with the stop as shown in Figure 2 c Set the burner assembly and top pan aside d The gas line...

Page 7: ...a Rock and Vermiculite a Rock Wool Place approximately 1 2 diameter pieces of rock wool on the top of the burner covering the front 2 3 of the burner Do not cover the rear row of burner ports The rock...

Page 8: ...notches in the log with the grate bars and pull the log forward until it comes into contact with the upright portion of the grate bars See Figure 10 c Top Right Log The top right log is supplied with...

Page 9: ...are installed in the battery pack Figure 13 M Series Intermittent Pilot Wiring Diagram b Battery Replacement 1 Access Cover Remove the access cover by locating the two hand tabs on either side of the...

Page 10: ...r Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water Due to high surface termperature...

Page 11: ...high surface termperatures keep children clothing and furniture away Keep burner and control compartment clean See installation and operating instructions accompanying the appliance LIGHTING INSTRUCTI...

Page 12: ...liquids Never obstruct the flow of combustion and ventilation air Keep the front of the appliance clear of all obstacles and materials Leave clearance of at least 36 from the front of the fireplace T...

Page 13: ...d or thrown on top of the logs 2 Fireplace Safety a To avoid personal injury do not touch hot surfaces when the appliance is operating b Always ensure that the fireplace screen is closed when the appl...

Page 14: ...Service Parts FI36M FI36ML Beginning Manufacturing Date N A Ending Manufacturing Date Active Part number list on following page Log Set Assembly Imperial 36 Gas Log Set 1 3 2 4 5 6 7 8 9 11 10 12 13 1...

Page 15: ...Module 593 592 Y 8 Brass Connector 303 315 5 Y 9 Valve NG 593 500 Y Valve LP 593 501 Y 10 Brass Male Connector 13425 11 Gas Tube 33729 12 Ori ce NG 152 32229 Y Ori ce LP 093 16752 Y 13 Bulkhead 13405A...

Page 16: ...bly 33743 6 Burner Assembly 33725 Y 7 Pilot Assembly NG 33993 Y Pilot Assembly LP 33994 Y 8 Pilot Bracket no longer available 33735 9 Gas Tube no longer available 33989 10 Brass Male Connector 13425 1...

Page 17: ...Service Parts Beginning Manufacturing Date N A Ending Manufacturing Date Active FI42M FI42ML Part number list on following page Log Set Assembly Imperial 42 Gas Log set 1 3 2 4 5 6 7 8 9 11 10 12 13 1...

Page 18: ...ss Connector Pkg of 5 303 315 5 Y 9 Valve NG 593 500 Y Valve LP 593 501 Y 10 Brass Male Connector 13425 11 Gas Tube 33729 12 Ori ce NG 182 32230 Ori ce LP 110 17235 Y 13 Bulkhead 13405A 14 Pilot Assem...

Page 19: ...19 33734 Rev N 6 15...

Page 20: ...he pilot hood Adjust gap to give proper spark Remove hands from electrode before attempting to spark e No gas supply to the appliance Check plumbing to ensure the appliance has been hooked up to the g...

Page 21: ...lit after carefully following lighting instructions a Thermocouple too tight or too loose Thermocouple must be attached to the valve finger tight plus a 1 8 turn with a wrench b Weak pilot flame Pilo...

Page 22: ...parts can be obtained from your dealer The wireless remote control switch is supplied with installation instructions packaged with them Should you need additional information please contact your deale...

Page 23: ...home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occ...

Page 24: ...as a result of normal use As a heating appliance some changes in color of interior and exterior surface finishes may occur This is not a flaw and is not covered under warranty Damage to printed plated...

Reviews: