Heatilator Fi36M Installation & Operating Instructions Manual Download Page 11

6/15 

33734 Rev N 

11

ImperIal Gas loG set InstallatIon InstructIons

F. operating Instructions for the “s” series

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may 

result causing property damage, personal injury or loss of life.

A.  This appliance has a pilot which must be lit by 

hand. When lighting the pilot, follow these 

instructions exactly.

C.  Use only your hand to push in or turn the gas control 

knob. Never use tools. If the knob will not push in or 

turn by hand, don't try to repair it, call a qualified 

service technician. Force or attempted repair may 

result in a fire or explosion.

B.  BEFORE LIGHTING smell all around the 

appliance area for gas. Be sure to smell next to 

the floor because some gas is heavier than air 

and will settle to the floor.   

 

 

WHAT TO DO IF YOU SMELL GAS

 

•  Do not try to light any appliance.

 

•  Do not touch any electric switch; do not use 

any phone in your building.

 

•  Immediately call your gas supplier?from a 

neighbor's phone. Follow the gas supplier's 

instructions.

 

•  If you cannot reach your gas supplier, call 

the fire department. 

D.  Do not use this appliance if any part has been under 

water. Immediately call a qualified service techni-

cian to inspect the appliance and to replace any 

part of the control system and any gas control 

which has been under water.

Due to high surface termperatures, keep children, clothing and furniture away.

Keep burner and control compartment clean. See installation and operating instructions accompanying the appliance.

LIGHTING INSTRUCTIONS

1. 

STOP! Read the safety instruction label.

5. 

Turn knob on control counterclockwise        to "PILOT".

3. 

Wait five minutes to clear out any gas. If you smell 

gas, STOP! Follow "B" on the safety information 

label. If you don't smell gas, go to next step.

4. 

Find pilot--follow metal tube from gas control. The 

pilot is behind the burner pan.

6. 

Push in the knob all the way and hold in. Immediately 

light the pilot with the use of a paper match and lighter 

rod. Continue to hold the control knob in for about one 

minute after the pilot is lit. Release button and it will pop 

back up. Pilot should remain lit. If it goes out, repeat 

steps 3 through 7.

 

If button does not pop up when released, stop and 

immediately call your service technician or gas supplier. 

If the pilot will not stay lit after several tries, turn the gas 

control knob to "OFF" and call your service technician 

or gas supplier.

7. 

Turn gas control knob counterclockwise         to "ON". 

Knob can be turned  to "ON" only if the control knob is 

popped out.

TO TURN OFF GAS APPLIANCE

1. 

Turn gas control clockwise          to "OFF. Do not force.

2.   Turn gas control knob clockwise           to "OFF".

PILOT 

BURNER

THERMOCOUPLE

34008

FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors and liquids in the vicinity of 

this or any other appliance.

Lighting Instructions for the “S” Series

Summary of Contents for Fi36M

Page 1: ...causing property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance What to do if you smell gas D...

Page 2: ...This will prevent possible electrical shock or burns Also make sure the fireplace is completely cooled before servicing 7 Solid fuels cannot be burned in a fireplace where the decorative gas appliance...

Page 3: ...erated as a system Any alteration to or substitution for items in this system unless allowed by these installation instruc tions will void the Underwriters Laboratories listing and may void the produc...

Page 4: ...to natural gas The conversion kits for all S series log sets are CKMP to convert from natural to propane gas CKMN to convert from propane to natural gas These HEATILATOR gas log sets and components h...

Page 5: ...t pressure equal to or less than 1 2 PSIG The minimum size fireplace in which the log set can be installed and the minimum permanent free opening that must be provided by either the fireplace chimney...

Page 6: ...l the Damper Stop To install the damper stop Open the damper to the fully open position and secure it open with the stop as shown in Figure 2 c Set the burner assembly and top pan aside d The gas line...

Page 7: ...a Rock and Vermiculite a Rock Wool Place approximately 1 2 diameter pieces of rock wool on the top of the burner covering the front 2 3 of the burner Do not cover the rear row of burner ports The rock...

Page 8: ...notches in the log with the grate bars and pull the log forward until it comes into contact with the upright portion of the grate bars See Figure 10 c Top Right Log The top right log is supplied with...

Page 9: ...are installed in the battery pack Figure 13 M Series Intermittent Pilot Wiring Diagram b Battery Replacement 1 Access Cover Remove the access cover by locating the two hand tabs on either side of the...

Page 10: ...r Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water Due to high surface termperature...

Page 11: ...high surface termperatures keep children clothing and furniture away Keep burner and control compartment clean See installation and operating instructions accompanying the appliance LIGHTING INSTRUCTI...

Page 12: ...liquids Never obstruct the flow of combustion and ventilation air Keep the front of the appliance clear of all obstacles and materials Leave clearance of at least 36 from the front of the fireplace T...

Page 13: ...d or thrown on top of the logs 2 Fireplace Safety a To avoid personal injury do not touch hot surfaces when the appliance is operating b Always ensure that the fireplace screen is closed when the appl...

Page 14: ...Service Parts FI36M FI36ML Beginning Manufacturing Date N A Ending Manufacturing Date Active Part number list on following page Log Set Assembly Imperial 36 Gas Log Set 1 3 2 4 5 6 7 8 9 11 10 12 13 1...

Page 15: ...Module 593 592 Y 8 Brass Connector 303 315 5 Y 9 Valve NG 593 500 Y Valve LP 593 501 Y 10 Brass Male Connector 13425 11 Gas Tube 33729 12 Ori ce NG 152 32229 Y Ori ce LP 093 16752 Y 13 Bulkhead 13405A...

Page 16: ...bly 33743 6 Burner Assembly 33725 Y 7 Pilot Assembly NG 33993 Y Pilot Assembly LP 33994 Y 8 Pilot Bracket no longer available 33735 9 Gas Tube no longer available 33989 10 Brass Male Connector 13425 1...

Page 17: ...Service Parts Beginning Manufacturing Date N A Ending Manufacturing Date Active FI42M FI42ML Part number list on following page Log Set Assembly Imperial 42 Gas Log set 1 3 2 4 5 6 7 8 9 11 10 12 13 1...

Page 18: ...ss Connector Pkg of 5 303 315 5 Y 9 Valve NG 593 500 Y Valve LP 593 501 Y 10 Brass Male Connector 13425 11 Gas Tube 33729 12 Ori ce NG 182 32230 Ori ce LP 110 17235 Y 13 Bulkhead 13405A 14 Pilot Assem...

Page 19: ...19 33734 Rev N 6 15...

Page 20: ...he pilot hood Adjust gap to give proper spark Remove hands from electrode before attempting to spark e No gas supply to the appliance Check plumbing to ensure the appliance has been hooked up to the g...

Page 21: ...lit after carefully following lighting instructions a Thermocouple too tight or too loose Thermocouple must be attached to the valve finger tight plus a 1 8 turn with a wrench b Weak pilot flame Pilo...

Page 22: ...parts can be obtained from your dealer The wireless remote control switch is supplied with installation instructions packaged with them Should you need additional information please contact your deale...

Page 23: ...home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occ...

Page 24: ...as a result of normal use As a heating appliance some changes in color of interior and exterior surface finishes may occur This is not a flaw and is not covered under warranty Damage to printed plated...