WS Series Wood Burner
FLOOR PROTECTOR
Heatilator WINS18 does require a insulating Floor Protector minimum 900mm deep, 800mm wide
and 75mm thick (clay bricks), as they are tested and comply with the minimum Floor Protector
requirements of
AS/NZS 2918:2001.
Note:
▪ The minimum Floor Protector sizes are specified in the clearance chart, see Fig. 3 and 4.
▪ A Floor Protector can include ceramic tiles with grouted joints fixed directly onto a wooden floor or
a sheet of toughened glass, panel steel or any other non combustible material laid directly onto a
wooden floor.
▪ If installed directly onto a concrete slab, the concrete slab can be considered as the floor
protector,but must maintain the minimum measurement listed.
NOTE: HEAT SHIELD REQUIREMENTS FOR HEAT SENSITIVE WALLS
Clearances may be reduced by provision of an appropriately located heat shield refer to
AS/NZS 2198:2001 3.2.3 TABLE 3.1
Fig. 3
MINIMUM CLEARANCES
Mantel
1050mm
250mm
300mm