Heatilator ECO CHOICE WINS18 Installation Instructions Manual Download Page 1

Page  1

7065-144A

April 7, 2014

Eco-Choice Insert Wood Burner Installation Instructions

INSTALLATIONS TO COMPLY WITH AS/NZS2918:2001 

AND WILL REQUIRE A BUILDING CONSENT

IMPORTANT: Read all instructions carefully before starting installation.  Failure to follow these 

instructions may result in a fire hazard and will void the warranty.

• 

Fig. 3,4,5,6, 7 and Table 1,2,3,4 relate to installations with tested flue systems; as per 

AS/NZS 

2918:2001 - Appendix F

, with a ceiling angle between 0° - 30° inclusive.

• 

For installations with a ceiling angle greater than 30°, refer to Fig. 7 & 8 and 

AS/NZS 2918:2001 

4.6.3(b)

• 

Ceiling Plate may vary in size depending on ceiling angle.  Please specify ceiling pitch prior to 

ordering the ceiling plate.

• 

Heatilator Eco Choice series wood burner’s are tested and approved to the N.Z. National Environ

-

mental Standards;

WINS18-AU Eco-Choice Hardwood Certified 

Particulate Emissions = 1.0 g/kg Space Heating Efficiency = 77%

Model:

WINS18-AU

Summary of Contents for ECO CHOICE WINS18

Page 1: ...to installations with tested flue systems as per AS NZS 2918 2001 Appendix F with a ceiling angle between 0 30 inclusive For installations with a ceiling angle greater than 30 refer to Fig 7 8 and AS NZS 2918 2001 4 6 3 b Ceiling Plate may vary in size depending on ceiling angle Please specify ceiling pitch prior to ordering the ceiling plate Heatilator Eco Choice series wood burner s are tested a...

Page 2: ...ily many years of enjoyment in the warmth and comfort of your hearth appliance Thank you for choosing Heatilator and Welcome to the Quadra Fire Family OVERALLAVERAGEEFFICIENCYBURNINGHARDWOOD WHENTESTEDINACCORDANCETOAS NZS4012 1999 77 AVERAGEPARTICULATEEMISSIONFACTORBURNINGHARDWOOD WHENTESTEDINACCORDANCE TOAS NZS4013 1999 1 0g kg MAXIMUMAVERAGEHEATOUTPUTBURNINGHARDWOOD 7 7kw APPROVEDFUEL BURNONLYHA...

Page 3: ...iew Figure 3 3 Side View Figure 3 2 Top View 24 1 4 in 616mm 15 11 16 in 398mm 9 7 16 in 240mm 33 1 4 in 845mm 10 1 2 in 267mm 10 1 2 in 267mm 5 3 16 in 132mm 21 1 16 in 534mm 6 1 16 in 154mm 4 1 2 in 114mm 7 5 16 in 186mm 20 in 508mm A B Surround Sizes A B SP WINS18 STD 1092mm 787mm SP WINS18 LRG 1295mm 864mm ...

Page 4: ...Protector can include ceramic tiles with grouted joints fixed directly onto a wooden floor or a sheet of toughened glass panel steel or any other non combustible material laid directly onto a wooden floor If installed directly onto a concrete slab the concrete slab can be considered as the floor protector but must maintain the minimum measurement listed NOTE HEAT SHIELD REQUIREMENTS FOR HEAT SENSI...

Page 5: ...April 7 2014 7065 144A Page 5 WS Series Wood Burner Fig 4 MINIMUM CLEARANCES CONT 800mm Mantle uprights must be less than 50mm thick ...

Page 6: ...s must be removable and replaceable for cleaning and re installation NOTE Refer to chimney liner manufacturer for recom mendations on supporting the liner Installation into fireplaces without a permit will void the listing A Venting Systems Chimney Connector It is also known as flue pipe or stove pipe It must be 152 mm minimum diameter stainless steel connector pipe Chimney The chimney can be new ...

Page 7: ...iciency and decrease creosote deposits in the chimney When a connected flue or liner is in use the insert is able to breathe better by allowing a greater draft to be created This great draft can decrease problems such as difficult start ups smoking out the door and dirty glass G Installation Into A Factory Built Fireplace 1 When installed in a factory built fireplace a full stainless steel rigid i...

Page 8: ...eel Liner or Other Approved Lining System Minimum 8 in 203mm Masonry Thickness in Front of Smoke Chamber Damper Plate Removed or Fastened in Open Position Seal with Non Combustible Material Minimum Clearance in Accordance with Insert Listing Floor Protection in Accordance with Insert Listing Follow Manufacturer s Instructions for Maximum Liner Extension Above Chimney Maximum 30 Degrees Offset in C...

Page 9: ...able Solution from 01 07 05 5 Install the outer casing so that i lower end is flush with the underside of the ceiling material and ii with the addition of metal L brackets affix to the outer casing at 90 degrees secure the outer casing centrally to the ceiling and roof nogs Alternatively substitute the L brackets for 25mm thick non heat sensitive packers Secure the outer casing through the packers...

Page 10: ...DOUS CONDITIONS WHERE SUCH ACTION IS CONSIDERED THE MAN UFACTURER SHOULD BE CONSULTED IN THE FIRST INSTANCE CAUTIONS CRACKED AND BROKEN COMPONENTS e g GLASS PANELS OR CERAMIC TILES MAY RENDER THE INSTALLATION UNSAFE WARNING ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN WRITING BY THE TESTING AUTHORITY IS CONSIDERED AS BREACHING AS NZS 4013 WARNING DO NOT USE FLAMMABLE LIQUIDS OR ...

Page 11: ...coverage under this manufacturer s warranty begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occurs earlier The warranty period for this manufacturer s warranty shall commence no later than 24 months following the date of product shipment from HHT regardless of the installation or occupan...

Page 12: ... supplied with the appliance or any other components not expressly authorized and approved by HHT 8 modification of the appliance not expressly authorized and approved by HHT in writing and or 9 interruptions or fluctuations of electrical power supply to the appliance Non HHT venting components hearth components or other accessories used in conjunction with the appliance Any part of a pre existing...

Page 13: ...April 7 2014 7065 144A Page 13 WS Series Wood Burner SERVICE MAINTENANCE LOG Date of Service Performed By Description of Service ...

Page 14: ...Page 14 7065 144A April 7 2014 WS Series Wood Burner Date of Service Performed By Description of Service SERVICE MAINTENANCE LOG ...

Page 15: ...April 7 2014 7065 144A Page 15 WS Series Wood Burner Date of Service Performed By Description of Service SERVICE MAINTENANCE LOG ...

Page 16: ...r phone Notes DO NOT DISCARD THIS MANUAL CAUTION Important operating and maintenance instruc tions included Leave this manual with party responsible for use and operation Read understand and follow these instruc tions for safe installa tion and operation DO NOT DISCARD Please contact your Heatilator dealer with any questions or concerns For the number of your nearest Heatilator dealer log onto www...

Reviews: