30 in. minimum
to ceiling
D. Mantel and Wall Projections
WARNING! Risk of Fire!
Comply with all minimum clear-
ances to combustibles as specified. Framing or finishing
material closer than the minimums listed must be construct-
ed entirely of non-combustible materials (i.e., steel studs,
concrete board, etc).
Figure 5.3 Minimum Vertical and Maximum Horizontal
Dimensions
Note:
All
measurements
in inches.
A 2 in. (51 mm) min.
from fireplace opening
to perpendicular wall
Mantel Leg or
Perpendicular Wall
Top of
Appliance
Drywall
A
Figure 5.4 Mantel Leg or Wall Projections (Acceptable on both
sides of opening)
Mantels
Mantel Legs or Wall Projections