48
Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17
Figure 9.6 Air Shutter Location
F. Air Shutter Setting
Air shutter settings may be adjusted by a qualified install
-
er at the time of installation.
The air shutter is set at the
factory for minimum vertical vent run. Adjust air shutter for
longer vertical runs. See Figure 9.6.
• Refer to Gas Service Access instructions in Section 9.C
to access the air shutter.
• Loosen the 1/4 in. screw.
Air Shutter Settings
CRAVE4836-B
CRAVE4836ST-B
CRAVE6048-B
CRAVE6048ST-B
NG
Propane
Appliance-Standard
3/16 in.
Full Open
With Glass Refractory
Installed
3/16 in.
Full Open
With Log Kit Installed
1/4 in.
Full Open
• Twist shutter to adjust.
• Shutter may be open for longer horizontal vent runs.
• Do not close the air shutter more than 1/16 in. for NG or
1/4 in. for propane.
• Tighten the screw.
NOTICE:
If sooting occurs, provide more air by opening
the air shutter.
CRAVE7260-B
CRAVE7260ST-B
NG
Propane
Appliance-Standard
3/8 in.
Full Open
With Glass Refractory
Installed
3/8 in.
Full Open
With Log Kit Installed
3/8 in.
Full Open
CRAVE8472-B
CRAVE8472ST-B
NG
Propane
Appliance-Standard
1/2 in.
Full Open
With Glass Refractory
Installed
1/2 in.
Full Open
With Log Kit Installed
1/2 in.
Full Open
DETAIL