16
Heatilator • CRAVE4836/ST-B, CRAVE6048/ST-B, CRAVE7260/ST-B, CRAVE8472/ST-B Installation Manual • 2301-973 Rev. H • 5/17
B. Clearances to Combustibles
When selecting a location for the appliance it is important
to consider the required clearances to walls. See Figure
3.8 and Figure 3.9.
WARNING! Risk of Fire or Burns!
Provide adequate
clearance around air openings and for service access.
Due to high temperatures, the appliance should be lo-
cated out of traffic and away from furniture and draperies.
NOTICE:
Illustrations reflect typical installations and are
FOR DESIGN PURPOSES ONLY. Illustrations/diagrams
are not drawn to scale. Actual installation could vary due
to individual design preference.
Figure 3.8 Appliance Locations: CRAVE Single-Sided Models
Model
A
B
C
D
E
F
G
CRAVE4836-B
Inches
62-1/2
48-1/4
88-1/8
See
Section
10, Figure
10.14 and
10.15.
24-1/2
18-3/4
1
Millimeters
1588
1226
2238
622
477
25
CRAVE6048-B
Inches
70-3/4
60-1/4
100-3/8
28-1/2
18-3/4
1
Millimeters
1797
1530
2550
724
476
25
CRAVE7260-B
Inches
79-1/2
72-1/4
112-3/8
31-3/4
18-3/4
1
Millimeters
2019
1835
2854
807
476
25
CRAVE8472-B
Inches
88
84-1/4
124-3/8
35-1/4
18-3/4
1
Millimeters
2235
2140
3159
895
476
25
It is important to follow the framing and finishing instruc
-
tions step by step to ensure proper placement of fireplace
in the surrounding framing/finishing materials.
B
C
A
B
G
F
E
B
G
D
Refer to Section 10 for hearth, mantel and
wall projection information.
If a HEAT-ZONE® HEAT-DUCT will be
installed, refer to Section 5.E for information.
2 HEAT-ZONES/HEAT-DUCTS = Add 4 IN. to dimension B
1 HEAT-ZONE/HEAT DUCT = Add 2 IN. to dimension B
B