Heatilator • CNXT4236IT-D, CNXT4842IT-D, CNXT4236IH-D, CNXT4842IH-D • 2360-900 Rev. i • 5/17
28
H
1
V
1
Figure 7.4
Top Vent - Horizontal Termination
Top Vent - Horizontal Termination
One Elbow
Note:
For corner installations: A 6 inch (152
mm) section of straight pipe may need to
be attached to the appliance before a 90º
elbow, to allow the vent pipe to clear the top
standoffs.
CNXT4842 Series
V
1
Minimum
H
1
Maximum
Elbow only
2 ft.
610 mm
1/2 ft.
152 mm
2 ft.
610 mm
1 ft.
305 mm
4 ft.
1.2 m
1-1/2 ft.
457 mm
6 ft.
1.8 m
2 ft.
610 mm
8 ft.
2.4 m
2-1/2 ft.
762 mm
8 ft.
2.4 m
3 ft.
914 mm
12 ft.
3.7 m
4 ft.
1.2 m
20 ft.
6.1 m
6 ft.
1.9 m
25 ft.
7.6 m
V
1
+ H
1
= 40 ft. (12.2 m) Maximum
H
1
= 25 ft. (7.6 m) Maximum
Fire Risk. Explosion Risk.
Do NOT pack insulation or other combustibles
between ceiling firestops.
• ALWAYS maintain specified clearances around
venting and firestop systems.
• Install wall shield and ceiling firestops as speci
-
fied.
Failure to keep insulation or other material away
from vent pipe may cause fire.
Example:
DVP pipe 3 ft. min. vertical = 11 ft. max. horizontal
SLP pipe 7 ft. min. vertical = 11 ft. max. horizontal
Fire Risk.
• When using DVP-HRC-SS and DVP-HRC-ZC-
SS termination caps on top vented fireplaces, a
6 inch minimum vertical vent section is required
before installing first elbow.
E. Vent
D
iagrams
WARNING
WARNING
Note: The CNXT series fireplaces can adapt to SLP series vent pipe,
if desired.
When venting off the top of the unit, use a DVP-2SL adapter and a
minimum 48 inch vertical section of SLP series vent pipe.
A DVP-SLP24 adapter may also be used with a 24 inch vertical
section of SLP series vent pipe.
After
the 48 inch vertical section, the venting table rules must be
followed. The first 48 inch
vertical
section is NOT counted as part of
the vertical components in the table. It is still counted as part of the
overall maximum run. All venting table rules for the vent run must
still be followed.
CNXT4236 Series
V
1
Minimum
H
1
Maximum
Elbow only
2 ft.
610 mm
1/2 ft.
152 mm
6 ft.
1.8 m
1 ft.
305 mm
11 ft.
3.4 m
1-1/2 ft.
457 mm
18 ft.
5.5 m
2 ft.
610 mm
25 ft.
7.6 m
V
1
+ H
1
= 40 ft. (12.2 m) Maximum
H
1
= 25 ft. (7.6 m) Maximum