51
Heatilator • CD4236IFTR, CD4236IFTLR, CD4842IFTR, CD4842IFTLR Installation Manual • 2511-980 Rev. M
• 8/21
10
10
Finishing
A. Facing Material
• Metal front faces may be covered with non-combustible
materials only.
• Facing and/or finishing materials must not interfere with
air flow through or removal of decorative fronts or access
for service.
• Facing and/or finishing materials must never overhang
into the glass opening.
• Observe all clearances when applying combustible
materials.
• Seal joints between the finished wall and appliance top
and sides using a 300 ºF minimum sealant. Refer to
Figure 10.1.
NOTICE:
Surface temperatures around the appliance will
become warm while the appliance is in operation. Ensure
finishing materials used for all surfaces (floor, walls,
mantels, etc.) will withstand temperatures up to 190
°
F.
Figure 10.1 Noncombustible Facing Diagram
A
B
CD4236
inches
39-3/4
41
millimeters
1010
1041
CD4842
inches
41-3/4
48
millimeters
1060
1219
B
A
FACTORY-INSTALLED NON-COMBUSTIBLE BOARD
DO NOT REMOVE
Finish wall material may be combustible - Top and Sides
Seal Top and Side Joints with High Temperature Sealant (300 °F/149 °C min.)
WARNING! Risk of Fire! DO NOT
apply combustible
materials beyond the minimum clearances. Comply with
all minimum clearances to combustibles as specified in
this manual. Overlapping materials could ignite and will
interfere with air flow through decorative fronts.