BUILDER'S CHOICE SERIES INSTALLATION INSTRUCTIONS
2. VERTICAL TERMINATION
a. Clearances
See Figure 13 for clearance information.
b. Vent Lengths
Various venting configurations are shown in
Figures 14 and 15 from which the maximum vent
runs can be determined.
Figure 13
Vent Clearances
Figure 14 - Vent Lengths
Figure 15
Vent Support
WARNING!
A gas appliance must not be connected to a chimney
flue servicing a separate solid fuel burning appliance.
WARNING - RISK OF FIRE!
Always maintain minimum clearances or greater
around the chimney system. Do not pack air spaces
with insulation or other material.
WARNING!
The horizontal run of vent must have a 1/4 rise for
every 1 of run towards the termination. Never allow
the vent to run downward. This could cause high tem-
peratures and present a fire hazard.