55
Heatilator • RAVE4013I-C • 2293-900 Rev. E • 2/13
The Deco and Illusion decorative fronts are approved for
inside fi t applications. Non-combustible fi nishing materi-
als up to 4 inches thick can be installed around the front
(left, right, top, and bottom).
For inside fi t applications, the decorative front must be in-
stalled tight to the fi nishing fl anges and must not overlap
any fi nish material.
The Deco front requires a 1/2 inch clearance between
the outer edge of the decorative front and inside edge of
the surrounding fi nish materials. HHT recommends that
the front be temporarily installed as a template, traced to
ensure the fi nishing materials will fi t properly, and then
removed.
FACTORY-INSTALLED
NON-COMBUSTIBLE
BOARD
DRYWALL OR
EQUIVALENT
(1/2 IN.)
20-1/2 IN. APPLIANCE
OPENING (HEIGHT)
3/4 IN.
3 IN.
0 - 4 IN.
0 - 4 IN.
Figure 13.10 Inside Fit Method (Deco Decorative Front Only)
Non-Combustible Finish Materials
0 Inches to 4 Inches Thick Inside Fit Method
Reference dimensions for the Deco and Illusion fronts installed
on the appliance are shown in Figure 13.13 and Figure 13.14.